{"product_id":"enervexc-adc100-fan-control","title":"Enervexc - ADC100 Fan Control","description":"\u003ch3\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0100\/7917\/4734\/files\/Enervex_AD_563aed3f-fde8-4482-ab4f-e62611ec6fa4_480x480.jpg?v=1611092279\" style=\"display: block; margin-left: auto; margin-right: auto;\" referrerpolicy=\"no-referrer\" width=\"150\" height=\"150\"\u003e\u003c\/h3\u003e\n\u003cdiv\u003eThe ENERVEX ADC100 Appliance Draft Control is used to control draft in systems where modulation is not required. It controls the speed of the fan to maintain proper pressure in the chimney. The ADC100 is for indoor installations only. The control can be used with Models RS and GSV Fans.\u003c\/div\u003e\n\u003cdiv\u003eThe ADC100 is typically used to control the draft of a gas-fired furnace, fireplace, stove, or pizza oven.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eThe ADC100 comes with an external PDS. The PDS is a NO\/NC switch that monitors the pressure in the chimney.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eThe ADC100 operates a chimney fan at a set speed to create and maintain proper mechanical draft at the outlet of a heating appliance(s). The control provides a 10-120 VAC signal to single phase fans, as well as a 0-10 VDC signal that can be used to control 3-phase fans by a variable frequency drive.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eThe ADC100 comes with an external PDS. The PDS is a NO\/ NC switch that monitors the pressure in the chimney. In case of inadequate draft, the PDS will open and if open for 15 seconds, the control will go into alarm mode and lock out the appliance until draft is restored.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eThe control features a manual and automatic adjustment mode which is selected via dipswitch. The PDS check function and manual or automatic reset function are also selected through a dipswitch.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eAn integrated damper relay allows a damper to be connected directly to the ADC100. The control ensures that the damper is fully open before allowing the appliance to operate by interlocking the damper end-switches to the control. In the event that the controller senses any mechanical failures, the control will initiate a retry sequence.\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eThe enclosure is made of NEMA 1 rated ABS plastic.\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eStandard Equipment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eADC 100 Control Box\u003c\/li\u003e\n\u003cli\u003ePDS Proven Draft Switch Box\u003c\/li\u003e\n\u003cli\u003eStack Probe\u003c\/li\u003e\n\u003cli\u003e6' Silicone Tubing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003eThe ADC100 Fan Control is ETL Listed in the U.S. and Canada:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eUL 508 Standard for Industrial Control Equipment (17th Ed.)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 14-05- Standard for Industrial Control Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003e2-Year Factory Warranty. Complete warranty conditions are available from ENERVEX Inc.\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0-10 VAC control signal and 10-120 VAC for variable speed\u003c\/li\u003e\n\u003cli\u003eFor indoor installations only\u003c\/li\u003e\n\u003cli\u003eFor use with RS Fans\u003c\/li\u003e\n\u003cli\u003eIncludes an external PDS Proven Draft Switch\u003c\/li\u003e\n\u003cli\u003eControls both 1x120V and 3x230V\/460V fan (three-phase fans require an EDrive)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e1 x 120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003eAmperage\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e6.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003eControl Signals\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e0-10 VAC (for VFD) and 120\/240 VAC (for direct connect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003eOutput\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e10-120VAC \/ 0-10VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003eControl Relays\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e(6) Max 120VAC\/8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003eEMC Standard\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003eEmission: EN50 081-1, Immunity: EN50 081-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e2 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003eListing Certification\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003eUL 378, Standard for Draft Equipment\u003cbr data-mce-fragment=\"1\"\u003eUL 60947, Standard for Industrial Control Panels\u003cbr data-mce-fragment=\"1\"\u003eCSA C22.2 No. 14-95, Standard for Industrial Control Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sysOverviewPara\"\u003e\n\u003ch3\u003e\u003cstrong\u003eDownloads\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff8000;\"\u003e\u003ca style=\"color: #ff8000;\" title=\"Enervex ADC100 Installation Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0591\/9912\/7740\/files\/ADC100_6-17_2.pdf?v=1692661521\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eProduct Brochure\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff8000;\"\u003e\u003ca style=\"color: #ff8000;\" title=\"Enervex ADC100 Installation Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0591\/9912\/7740\/files\/ADC100_IO_Manual-05-17.pdf?v=1692661521\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAbout The Manufacturer: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0591\/9912\/7740\/files\/Enervex_AD_480x480_3b74c08e-48a1-4ca1-b270-5720bf40a1d1_240x240.webp?v=1692662751\" style=\"margin-bottom: 16px; float: none;\" referrerpolicy=\"no-referrer\"\u003e\u003c\/div\u003e\n\u003cdiv\u003eENERVEX provides a full line of listed, fully integrated commercial venting and mechanical draft control systems for a truly one-stop design from boiler outlet to chimney termination. ENERVEX products are economical, environmentally sustainable, aesthetically pleasing, reliable, and up to code for commercial projects around the globe. \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Enervex","offers":[{"title":"Default Title","offer_id":48510319362298,"sku":"302.0100.1200","price":1139.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/enervex-enervexc-adc100-fan-control-8268470.jpg?v=1774458790","url":"https:\/\/agentbbq.com\/products\/enervexc-adc100-fan-control","provider":"Agent BBQ","version":"1.0","type":"link"}