{"product_id":"enervex-adc150-fan-control","title":"Enervex - ADC150 Fan Control","description":"\u003cp class=\"sysOverviewPara\"\u003eThe ENERVEX ADC150 is a Modulating Fan Control used with up to 2 appliances to monitor and maintain a constant draft or pressure in a chimney or duct. The ADC150 can be used with models RS, RSHT, and GSV fans. It can control the fan speed directly or via a Variable Frequency Drive (VFD, sold separately). The ADC150 is typically used to control the draft of a gas-fired, sealed fireplace or water heaters.\u003c\/p\u003e\n\u003cdiv class=\"sysOverviewPara\"\u003eThe ADC150 monitors the draft in a chimney system via a connection to a pressure transducer (XTP) attached to the chimney, and maintains the draft by modulating the fan speed. It provides a 10-120V AC power to single phase fans and 0-10V DC control signal to control 3-phase fans via a variable frequency drive.\u003c\/div\u003e\n\u003cdiv class=\"sysOverviewPara\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"sysOverviewPara\"\u003eThe control has an integrated safety system that assures the heating appliance(s) is shut down in case of insufficient draft after 15-180 seconds (user adjustable). The ADC150 has an integrated damper relay that works with ENERVEX MFD (Mechanical Fireplace Damper) to automatically open the damper prior to fan initialization and close the damper after the appliance shuts down. End-switches in the damper actuator wired to the ADC150 ensure the damper must be fully open prior to allowing the appliance to operate. The control also features a post purge function (3 min) to evacuate the chimney system of residual flue gases after the appliance shuts down.\u003c\/div\u003e\n\u003ch3 class=\"sysOverviewPara\"\u003e \u003c\/h3\u003e\n\u003ch3 class=\"sysOverviewPara\"\u003eMaterial\u003c\/h3\u003e\n\u003cdiv class=\"sysOverviewPara\"\u003eThe enclosure is made of NEMA 1 rated ABS plastic.\u003c\/div\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eStandard Equipment \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eADC150 Control Box\u003c\/li\u003e\n\u003cli\u003eXTP Pressure Transducer\u003c\/li\u003e\n\u003cli\u003eStack Probe\u003c\/li\u003e\n\u003cli\u003e6' Silicone Tubing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eListings\u003c\/h3\u003e\n\u003cp\u003eThe ADC150 Fan Control is ETL Listed in the U.S. and Canada:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 508 Standard for Industrial Control Equipment (17th Ed.)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 14-05 - Standard for Industrial Control Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2-Year Factory Warranty. Complete warranty conditions are available from ENERVEX Inc.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQuiet Operation\u003c\/li\u003e\n\u003cli\u003eThe 0-10VDC control signal for EDrive and 10-120VAC for variable speed\u003c\/li\u003e\n\u003cli\u003eIntegrated safety system with adjustable shutdown time\u003c\/li\u003e\n\u003cli\u003eIntegrated damper relay that works with an EcoDamper.\u003c\/li\u003e\n\u003cli\u003eEnd-switches in an EcoDamper actuator can be wired to the ADC150\u003c\/li\u003e\n\u003cli\u003ePost purge function (180 sec) to evacuate residual flue gases after the fireplace shuts down.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e1 x 120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e6.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eControl Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003eContinuous or Intermittent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eControl Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e0-10 VAC (for VFD) and 120\/240 VAC (for direct connect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eRange Of Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e0-0.6 inWC \/ 0-150 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eTolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e0.01 inW (3 Pa) +\/- 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e10-120VAC \/ 0-10VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eControl Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e(6) Max 120VAC\/8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eEMC Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003eEmission: EN50 081-1, Immunity: EN50 081-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eInsulation Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003eNEMA 1 (IP 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003e2-Year Factory Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd class=\"colLeft\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eListing Certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"colRight\" data-mce-fragment=\"1\"\u003eUL 60947, Standard for Industrial Control Panels\u003cbr data-mce-fragment=\"1\"\u003eCSA C22.2 No. 14-95, Standard for Industrial Control Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eDownloads\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff8000;\"\u003e\u003ca style=\"color: #ff8000;\" title=\"Enervex ADC150 Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0591\/9912\/7740\/files\/ADC_150_6-17.pdf?v=1692663344\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eProduct Brochure\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff8000;\"\u003e\u003ca style=\"color: #ff8000;\" title=\"Enervex ADC150 Installation Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0591\/9912\/7740\/files\/ADC150_IO_Manual-05-17.pdf?v=1692663345\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eAbout The Manufacturer: \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0591\/9912\/7740\/files\/Enervex_AD_480x480_3b74c08e-48a1-4ca1-b270-5720bf40a1d1_240x240.webp?v=1692662751\" style=\"margin-bottom: 16px; float: none;\" referrerpolicy=\"no-referrer\"\u003e\u003c\/div\u003e\n\u003cdiv\u003eENERVEX provides a full line of listed, fully integrated commercial venting and mechanical draft control systems for a truly one-stop design from boiler outlet to chimney termination. ENERVEX products are economical, environmentally sustainable, aesthetically pleasing, reliable, and up to code for commercial projects around the globe. \u003c\/div\u003e","brand":"Enervex","offers":[{"title":"Default Title","offer_id":48510318018810,"sku":"302.0200.1200","price":2395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/enervex-enervex-adc150-fan-control-8950639.jpg?v=1774458368","url":"https:\/\/agentbbq.com\/products\/enervex-adc150-fan-control","provider":"Agent BBQ","version":"1.0","type":"link"}