{"title":"SunStar","description":null,"products":[{"product_id":"sunstar-stainless-portable-patio-heater-phs40-l6","title":"SunStar Stainless Portable Propane Patio Heater PHS40-L6","description":"\u003cdiv class=\"pc-parent-section-container\"\u003e\n    \u003cdiv class=\"pc-ai-features-and-specs-section undefined\"\u003e\n      \u003cdiv class=\"pc-content-flow\"\u003e\n        \u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\u003ch2\u003eSunStar PHS Stainless Portable Patio Heater Features\u003c\/h2\u003e\u003c\/div\u003e\n        \u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40,000 BTU Portable Propane Patio Heater\u003c\/strong\u003e: Puts out 40,000 BTU\/hr and spreads it evenly over a 20 ft diameter circle, enough to keep a full table or a small group warm outdoors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Electricity Needed\u003c\/strong\u003e: Runs entirely on a standard 20 lb propane cylinder with a matchless piezo ignition. Set it anywhere on the patio without running a cord.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt In Safety\u003c\/strong\u003e: UL listed with a flame failure safety device as standard, plus a weighted base that helps prevent tip over.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWheel Kit Included\u003c\/strong\u003e: Roll the heater to where people are sitting, and out of the way for storage at the end of the season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCup Holders In The Base\u003c\/strong\u003e: Four cup holders built into the base, each holding up to a 32 oz cup, so guests have somewhere to set drinks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless Steel Finish\u003c\/strong\u003e: A stainless steel finish that holds up outdoors and looks at home on a restaurant patio or a modern backyard.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"pc-content-flow\"\u003e\n        \u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\u003ch2\u003eSunStar PHS Stainless Portable Patio Heater Specs\u003c\/h2\u003e\u003c\/div\u003e\n        \u003cdiv class=\"pc-ai-table-container null\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePHS40-L6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Type\u003c\/td\u003e\n\u003ctd\u003eLiquid propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e40,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Pattern\u003c\/td\u003e\n\u003ctd\u003e360 degree radiant, about 20' diameter circle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Supply\u003c\/td\u003e\n\u003ctd\u003eStandard 20 lb propane cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eMatchless piezo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectricity Required\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eUL listed, flame failure safety device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase\u003c\/td\u003e\n\u003ctd\u003eWeighted, helps prevent tip over, 4 cup holders (up to 32 oz each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobility\u003c\/td\u003e\n\u003ctd\u003ePortable wheel kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003cdiv class=\"pc-ai-accordian-section pc-ai-faq-section-mini-container pc-content-flow-mini\"\u003e\n      \u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\u003ch2\u003eSunStar PHS Stainless Portable Patio Heater FAQ\u003c\/h2\u003e\u003c\/div\u003e\n      \u003cdiv class=\"pc-ai-details-summary-container\"\u003e\n\u003cdetails\u003e\u003csummary\u003eHow much area does the PHS heat?\u003c\/summary\u003e\u003cp\u003eSunStar rates it for a 20 ft diameter circle of radiant heat. Wind and an open sky shrink that, so on breezy nights keep the seating close.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat size propane tank does it take?\u003c\/summary\u003e\u003cp\u003eA standard 20 lb propane cylinder, the same tank used on most gas grills. It sits inside the weighted base.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eDoes it need power to light?\u003c\/summary\u003e\u003cp\u003eNo. It uses a matchless piezo ignition and needs no electricity at all.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs this portable propane patio heater safe around guests?\u003c\/summary\u003e\u003cp\u003eIt is UL listed, has a flame failure device that shuts off the gas if the flame goes out, and a weighted base to help prevent tip over. Follow the clearances in the manual linked below.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I get a cover for it?\u003c\/summary\u003e\u003cp\u003eYes. The SunStar black heater cover (44033000) is listed under the optional add-ons below.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is the difference between the PHJ and PHS?\u003c\/summary\u003e\u003cp\u003eThe heater, output and features are the same. The PHJ is a black and silver texturized painted finish; the PHS is stainless steel.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWho can help me choose the right model?\u003c\/summary\u003e\u003cp\u003eCall BBQ Generals at (800) 375-3243. We can help with sizing, gas type, mounting and the add-ons your install needs.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n\u003cdiv class=\"pc-content-flow\"\u003e\n        \u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\n\u003ch5\u003e\u003ca href=\"https:\/\/sunstarheating.com\/wp-content\/uploads\/2022\/09\/PHJ-Spec-2.pdf\" rel=\"noopener\"\u003ePHS Specifications\u003c\/a\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003ca href=\"https:\/\/sunstarheating.com\/wp-content\/uploads\/2022\/09\/PHJ-IO-1.pdf\" rel=\"noopener\"\u003ePHS Installation and Operation Manual\u003c\/a\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003ca href=\"https:\/\/sunstarheating.com\/wp-content\/uploads\/2022\/09\/PHJ-Warranty.pdf\" rel=\"noopener\"\u003ePHS Warranty\u003c\/a\u003e\u003c\/h5\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n\u003cdiv class=\"pc-content-flow\"\u003e\n        \u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\u003ch2\u003eSunStar PHS Stainless Portable Patio Heater Optional Add-Ons\u003c\/h2\u003e\u003c\/div\u003e\n        \u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeater Cover, Black (Optional)\u003c\/strong\u003e: \u003cul\u003e\u003cli\u003eSunStar Heater Cover, Black (44033000): +$40.00\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n      \u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420365713658,"sku":"PHS40-L6","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/PHS.jpg?v=1795638583"},{"product_id":"sunstar-wall-ceiling-telescopic-mounting-bracket-kit-for-infrared-patio-heaters","title":"SunStar Wall Or Ceiling Telescopic Mounting Bracket Kit For Infrared Patio Heaters","description":"\u003cp\u003e\u003cstrong\u003eSunStar products are made to \u003c\/strong\u003e\u003cstrong\u003eorder. Estimated lead time is 4-6 Weeks.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWall \/ Ceiling Telescopic Mounting Bracket Kit - 15\" - 30\" overhead space (check clearances to combustibles space above before ordering) includes both 15 - 22\" and 22 - 30\" extension legs. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003cul class=\"last\"\u003e\n\u003cli\u003eWall \/ Ceiling Telescopic Mounting Bracket Kit- 15\"-30\" overhead space\u003c\/li\u003e\n\u003cli\u003eBlack Powder Coat Painted\u003c\/li\u003e\n\u003cli\u003eHardware included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e24.0 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e18.0\" L x 10.0\" W x 12.0\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420365746426,"sku":"44560352","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-WallCeiling-Telescopic-Mounting-Bracket-Kit-for-Infrared-Patio-Heaters.jpg?v=1795638586"},{"product_id":"sunstar-stainless-steel-gas-connector-for-infrared-patio-heaters","title":"SunStar Stainless Steel Gas Connector For Infrared Patio Heaters","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eGas Connector – Black Powder Coated Paint to match the heater. 1\/2in.OD -24in. Long with 1\/2MIP X 1\/2 FIP Connection.\u003c\/p\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e3.0 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan class=\"keyspectype\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e24.0\" L x 0.5\" H x 0.5\" W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420366827770,"sku":"30302241","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Stainless-Steel-Gas-Connector-for-Infrared-Patio-Heaters.jpg?v=1795638590"},{"product_id":"sunstar-marine-grade-telescopic-mounting-bracket-15-30","title":"SunStar Glass SS Marine Grade Wall\/Ceiling Telescopic Mounting Bracket 15”-30” Overhead Space","description":"\u003csection class=\"fa-product-page\"\u003e\u003cheader class=\"fa-product-hero\"\u003e\u003c\/header\u003e\n\u003csection class=\"fa-section\"\u003e\n\u003ch2\u003eAdjustable Marine-Grade Mounting Solution for SunStar Glass Patio Heaters\u003c\/h2\u003e\n\u003cp\u003eThis telescopic mounting bracket gives installers the flexibility needed to position compatible SunStar Glass Series patio heaters in outdoor residential and commercial spaces. The kit includes both 15\"-22\" and 22\"-30\" extension legs, making it suitable for applications where heater placement, overhead spacing, and clearance to combustible materials must be carefully managed.\u003c\/p\u003e\n\u003cp\u003eThe marine-grade stainless steel construction is ideal for demanding outdoor environments, including coastal patios, restaurant seating areas, resorts, outdoor bars, verandas, and covered entertainment spaces.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"fa-section\"\u003e\n\u003ch2\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003cdiv class=\"fa-feature-grid\"\u003e\n\u003cdiv class=\"fa-feature-card\"\u003e\n\u003cp\u003e\u003cstrong\u003e• Marine-Grade Stainless Steel:\u003c\/strong\u003e Provides strong corrosion resistance for outdoor, coastal, and high-humidity installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• 15–30 Inch Telescopic Range:\u003c\/strong\u003e Allows adjustable heater positioning below the wall or ceiling mounting surface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Wall or Ceiling Installation:\u003c\/strong\u003e Supports flexible mounting configurations for compatible SunStar Glass patio heaters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Two Extension Sets Included:\u003c\/strong\u003e Includes both 15–22 inch and 22–30 inch extension legs for installation flexibility.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"fa-section\"\u003e\n\u003ch2\u003eBest For\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor restaurant patios\u003c\/li\u003e\n\u003cli\u003eCovered residential patios\u003c\/li\u003e\n\u003cli\u003eCoastal properties\u003c\/li\u003e\n\u003cli\u003eHospitality venues and resorts\u003c\/li\u003e\n\u003cli\u003eOutdoor bars and entertainment areas\u003c\/li\u003e\n\u003cli\u003eInstallations requiring adjustable heater positioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"fa-section\"\u003e\n\u003ch2\u003eNot Recommended For\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNon-compatible SunStar heater models\u003c\/li\u003e\n\u003cli\u003eInstallations where combustible clearances cannot be maintained\u003c\/li\u003e\n\u003cli\u003eApplications outside SunStar installation guidelines\u003c\/li\u003e\n\u003cli\u003eMounting surfaces that cannot support the heater and bracket assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"fa-section\"\u003e\u003c\/section\u003e\n\u003csection class=\"fa-section\"\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSunStar Glass SS Marine Grade Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/li\u003e\n\u003cli\u003e15\"-22\" extension legs\u003c\/li\u003e\n\u003cli\u003e22\"-30\" extension legs\u003c\/li\u003e\n\u003cli\u003eMounting bracket components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"fa-section\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"fa-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSunStar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Name\u003c\/th\u003e\n\u003ctd\u003eSunStar Glass SS Marine Grade Wall\/Ceiling Telescopic Mounting Bracket 15\"-30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003ePatio Heater Mounting Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eMarine Grade Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Options\u003c\/th\u003e\n\u003ctd\u003eWall or Ceiling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExtension Range\u003c\/th\u003e\n\u003ctd\u003e15\"-30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded Extension Legs\u003c\/th\u003e\n\u003ctd\u003e15\"-22\" and 22\"-30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eOutdoor Patio Heater Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended Use\u003c\/th\u003e\n\u003ctd\u003eResidential and Commercial Outdoor Heating Installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection class=\"fa-section fa-expert-note\"\u003e\u003c\/section\u003e\n\u003c\/section\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420367057146,"sku":"44560355","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/sunstar-glass-ss-marine-grade-wall-ceiling-telescopic-mounting-bracket-15-30-overhead-space-heater-parts-accessories-44560355-flame-authority-1244818791.png?v=1795638593"},{"product_id":"sunstar-10-glass-ss-marine-grade-ceiling-mount-bracket-kit","title":"SunStar 10” Glass SS Marine Grade Ceiling Mount Bracket Kit","description":"\u003csection class=\"fa-product-description\"\u003e\n\u003ch2\u003eSecure, Low-Clearance Ceiling Mounting for SunStar Glass Series Infrared Heaters\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSunStar 10-Inch Marine Grade Stainless Steel Ceiling Mount Bracket Kit\u003c\/strong\u003e is a fixed-mount installation solution designed for compatible SunStar Glass Series infrared patio heaters. Constructed from marine-grade stainless steel, this bracket kit provides strong corrosion resistance for outdoor environments, including coastal locations, restaurants, hospitality venues, and residential outdoor living spaces.\u003c\/p\u003e\n\u003cp\u003eFeaturing a fixed 10-inch ceiling drop, this mounting kit positions the heater close to the mounting surface while maintaining a clean, professional appearance. Mounting hardware is included for convenient installation. When installing beneath a combustible ceiling, a compatible SunStar heat shield kit is required to reduce clearance requirements and allow safe installation at the 10-inch mounting height.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine-grade stainless steel construction:\u003c\/strong\u003e Resists corrosion in outdoor and coastal environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed 10-inch ceiling drop:\u003c\/strong\u003e Provides a secure, low-profile overhead mounting solution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for outdoor heater installations:\u003c\/strong\u003e Ideal for patios, restaurants, hospitality spaces, verandas, pergolas, and outdoor dining areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware included:\u003c\/strong\u003e Includes mounting hardware for a streamlined installation process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with heat shield systems:\u003c\/strong\u003e Supports reduced clearance installations when paired with the required SunStar heat shield.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional finished appearance:\u003c\/strong\u003e Creates a clean ceiling-mounted installation for compatible SunStar Glass Series heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBest For\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRestaurants with covered outdoor seating\u003c\/li\u003e\n\u003cli\u003eHospitality and commercial patio heating projects\u003c\/li\u003e\n\u003cli\u003eCoastal installations exposed to moisture or salt air\u003c\/li\u003e\n\u003cli\u003eResidential covered patios and outdoor living areas\u003c\/li\u003e\n\u003cli\u003eVerandas, pergolas, and outdoor dining spaces\u003c\/li\u003e\n\u003cli\u003eProfessional infrared heater installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot Recommended For\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNon-compatible heater models\u003c\/li\u003e\n\u003cli\u003eAdjustable-height mounting applications\u003c\/li\u003e\n\u003cli\u003eInstallations without adequate structural support\u003c\/li\u003e\n\u003cli\u003eCombustible ceiling installations without the required heat shield\u003c\/li\u003e\n\u003cli\u003eIndoor applications requiring adjustable suspension systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis ceiling mount bracket kit is designed for compatible \u003cstrong\u003eSunStar Glass Series infrared patio heaters\u003c\/strong\u003e, including applicable Marine Grade Glass Series installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo not use this bracket with non-Glass Series SunStar heaters or third-party heater brands unless compatibility is specifically confirmed by the manufacturer.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eInstallation Requirements\u003c\/h2\u003e\n\u003cp\u003eThe SunStar 10-Inch Ceiling Mount Bracket Kit is intended for fixed overhead installation. The mounting surface must be structurally capable of supporting the heater and bracket assembly.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHardware is included.\u003c\/li\u003e\n\u003cli\u003eHeat shield is sold separately.\u003c\/li\u003e\n\u003cli\u003eA compatible SunStar heat shield must be used when installing beneath a combustible ceiling.\u003c\/li\u003e\n\u003cli\u003eInstallation must follow SunStar clearance requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation must comply with applicable local building codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Do not install this bracket 10 inches below a combustible ceiling without the required SunStar heat shield kit.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSunStar 10-Inch Marine Grade Stainless Steel Ceiling Mount Bracket Kit\u003c\/li\u003e\n\u003cli\u003eMounting hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSold Separately\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSunStar Heat Shield Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCeiling Mount Bracket Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eFixed Ceiling Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Length\u003c\/td\u003e\n\u003ctd\u003e10 Inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eMarine Grade Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Resistant\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Rated\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Shield Included\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Shield Required for Combustible Ceilings\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003ePermanent Fixed Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Product Line\u003c\/td\u003e\n\u003ctd\u003eSunStar Glass Series Patio Heaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420367352058,"sku":"44560356","price":294.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/sunstar-10-glass-ss-marine-grade-ceiling-mount-bracket-kit-heater-parts-accessories-44560356-flame-authority-1244693477.png?v=1795638597"},{"product_id":"sunstar-sgl35-l7-mg-marine-grade-radiant-patio-heater-propane","title":"SunStar SGL35-L7-MG Marine-Grade Radiant Patio Heater – Propane","description":"\u003cp\u003eSGL35-L7-MG is a propane radiant patio heater with 316 stainless steel marine-grade housing.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e35,000 BTU\/hr high input and 24,000 BTU\/hr low input; propane model.\u003c\/li\u003e\n\u003cli\u003e316 stainless steel marine-grade housing.\u003c\/li\u003e\n\u003cli\u003eCeramic glass radiant heating with direct spark ignition.\u003c\/li\u003e\n\u003cli\u003eElectrical supply: 120V AC, 60 Hz, single phase, 0.4A. Gas connection: 1\/2-inch NPT male.\u003c\/li\u003e\n\u003cli\u003eOutdoor residential and commercial use. Indoor use is limited to approved commercial\/industrial applications; not for indoor residential dwellings.\u003c\/li\u003e\n\u003cli\u003eN7\/L7 configuration has a high\/low gas valve. External control selection is separate from the heater.\u003c\/li\u003e\n\u003cli\u003eHeat shield and mounting hardware are separate accessories unless specified in the purchased kit.\u003c\/li\u003e\n\u003cli\u003eWithout a heat shield, horizontal outdoor minimum clearances are 22 inches above, 20 inches to the sides, 12 inches at ends and 40 inches below.\u003c\/li\u003e\n\u003cli\u003eAngled mounting, shield-equipped installations and indoor installations have different clearances. Follow the corresponding installation-manual diagrams.\u003c\/li\u003e\n\u003cli\u003eHanging centers: 48 inches. This is mounting spacing, not overall heater length.\u003c\/li\u003e\n\u003cli\u003eBody cross-section: 9.6 inches high by 11.8 inches. See the dimensional drawing for installation.\u003c\/li\u003e\n\u003cli\u003eShipping weight: 55 lb. Source carton dimensions: 15\" X 16\" X 57\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2022\/02\/MG-Patio-Heater-w-heatshield-R131.pdf\" rel=\"noopener\"\u003eBrochure \/ specification sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2022\/06\/44201540-IO-SGL-Series-Patio-Heater-MG-8-sided-rev-April-2022-A.pdf\" rel=\"noopener\"\u003eInstallation, owner instructions and warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420367384826,"sku":"44629010","price":2263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL35-L7-MG-Marine-Grade-Radiant-Patio-Heater-Propane_34564__01744.1790133066.1280.1280.jpg?v=1795638601"},{"product_id":"sunstar-sgl35-marine-grade-316-stainless-heat-shield-kit-44566350","title":"SunStar SGL35 Marine-Grade 316 Stainless Heat Shield Kit – 44566350","description":"\u003cp\u003eSunStar SGL35 Marine-Grade 316 Stainless Heat Shield Kit – 44566350\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStainless Steel 316 - Heat Shield Kit - to reduce Clearances to Combustibles above.\u003c\/li\u003e\n\u003cli\u003eSeparately sold accessory; heater not included.\u003c\/li\u003e\n\u003cli\u003eShipping weight: 11 lb.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2022\/03\/44201540-IO-SGL-Series-Patio-Heater-Accessories.pdf\" rel=\"noopener\"\u003eMarine-grade accessory guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2022\/06\/44201540-IO-SGL-Series-Patio-Heater-MG-8-sided-rev-April-2022-A.pdf\" rel=\"noopener\"\u003eMarine-grade heater installation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420367679738,"sku":"44566350","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL35-Marine-Grade-316-Stainless-Heat-Shield-Kit-44566350_34551__31442.1790133041.1280.1280.webp?v=1795638605"},{"product_id":"sunstar-sgl35-two-stage-remote-control-retrofit-kit-44640010","title":"SunStar SGL35 Two-Stage Remote Control Retrofit Kit – 44640010","description":"\u003cp\u003eSunStar SGL35 Two-Stage Remote Control Retrofit Kit – 44640010\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eKit, Remote Control\u003c\/li\u003e\n\u003cli\u003eSeparately sold accessory; heater not included.\u003c\/li\u003e\n\u003cli\u003eManufacturer retrofit kit for existing two-stage SGL35-N7\/L7 heaters; qualified installation is required. See the retrofit instructions for the included components and installation procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2022\/02\/44201630-Form-Retrofit-Remote-Control-SUNSTAR.pdf\" rel=\"noopener\"\u003eRemote retrofit installation instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420367712506,"sku":"44640010","price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL35-Two-Stage-Remote-Control-Retrofit-Kit-44640010_34547__46583.1790133033.1280.1280.jpg?v=1795638609"},{"product_id":"sunstar-sgl35-n10-mg-marine-grade-radiant-patio-heater-natural-gas","title":"SunStar SGL35-N10-MG Marine-Grade Radiant Patio Heater – Natural Gas","description":"\u003cp\u003eSGL35-N10-MG is a natural gas radiant patio heater with 316 stainless steel marine-grade housing.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e35,000 BTU\/hr high input and 24,000 BTU\/hr low input; natural gas model.\u003c\/li\u003e\n\u003cli\u003e316 stainless steel marine-grade housing.\u003c\/li\u003e\n\u003cli\u003eCeramic glass radiant heating with direct spark ignition.\u003c\/li\u003e\n\u003cli\u003eElectrical supply: 120V AC, 60 Hz, single phase, 0.4A. Gas connection: 1\/2-inch NPT male.\u003c\/li\u003e\n\u003cli\u003eOutdoor residential and commercial use. Indoor use is limited to approved commercial\/industrial applications; not for indoor residential dwellings.\u003c\/li\u003e\n\u003cli\u003eRemote handset, batteries and High\/Low\/Off switch are included with this N10\/L10 configuration.\u003c\/li\u003e\n\u003cli\u003eHeat shield and mounting hardware are separate accessories unless specified in the purchased kit.\u003c\/li\u003e\n\u003cli\u003eWithout a heat shield, horizontal outdoor minimum clearances are 22 inches above, 20 inches to the sides, 12 inches at ends and 40 inches below.\u003c\/li\u003e\n\u003cli\u003eAngled mounting, shield-equipped installations and indoor installations have different clearances. Follow the corresponding installation-manual diagrams.\u003c\/li\u003e\n\u003cli\u003eHanging centers: 48 inches. This is mounting spacing, not overall heater length.\u003c\/li\u003e\n\u003cli\u003eBody cross-section: 9.6 inches high by 11.8 inches. See the dimensional drawing for installation.\u003c\/li\u003e\n\u003cli\u003eShipping weight: 55 lb. Source carton dimensions: 15\" X 16\" X 57\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2022\/02\/MG-Patio-Heater-w-heatshield-R131.pdf\" rel=\"noopener\"\u003eBrochure \/ specification sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2022\/06\/44201540-IO-SGL-Series-Patio-Heater-MG-8-sided-rev-April-2022-A.pdf\" rel=\"noopener\"\u003eInstallation, owner instructions and warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420367745274,"sku":"44629040","price":2528.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL35-N10-MG-Marine-Grade-Radiant-Patio-Heater-Natural-Gas_34567__83076.1790133070.1280.1280.jpg?v=1795638613"},{"product_id":"sunstar-sgl35-n7-mg-marine-grade-radiant-patio-heater-natural-gas","title":"SunStar SGL35-N7-MG Marine-Grade Radiant Patio Heater – Natural Gas","description":"\u003cp\u003eSGL35-N7-MG is a natural gas radiant patio heater with 316 stainless steel marine-grade housing.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e35,000 BTU\/hr high input and 24,000 BTU\/hr low input; natural gas model.\u003c\/li\u003e\n\u003cli\u003e316 stainless steel marine-grade housing.\u003c\/li\u003e\n\u003cli\u003eCeramic glass radiant heating with direct spark ignition.\u003c\/li\u003e\n\u003cli\u003eElectrical supply: 120V AC, 60 Hz, single phase, 0.4A. Gas connection: 1\/2-inch NPT male.\u003c\/li\u003e\n\u003cli\u003eOutdoor residential and commercial use. Indoor use is limited to approved commercial\/industrial applications; not for indoor residential dwellings.\u003c\/li\u003e\n\u003cli\u003eN7\/L7 configuration has a high\/low gas valve. External control selection is separate from the heater.\u003c\/li\u003e\n\u003cli\u003eHeat shield and mounting hardware are separate accessories unless specified in the purchased kit.\u003c\/li\u003e\n\u003cli\u003eWithout a heat shield, horizontal outdoor minimum clearances are 22 inches above, 20 inches to the sides, 12 inches at ends and 40 inches below.\u003c\/li\u003e\n\u003cli\u003eAngled mounting, shield-equipped installations and indoor installations have different clearances. Follow the corresponding installation-manual diagrams.\u003c\/li\u003e\n\u003cli\u003eHanging centers: 48 inches. This is mounting spacing, not overall heater length.\u003c\/li\u003e\n\u003cli\u003eBody cross-section: 9.6 inches high by 11.8 inches. See the dimensional drawing for installation.\u003c\/li\u003e\n\u003cli\u003eShipping weight: 55 lb. Source carton dimensions: 15\" X 16\" X 57\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2022\/02\/MG-Patio-Heater-w-heatshield-R131.pdf\" rel=\"noopener\"\u003eBrochure \/ specification sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2022\/06\/44201540-IO-SGL-Series-Patio-Heater-MG-8-sided-rev-April-2022-A.pdf\" rel=\"noopener\"\u003eInstallation, owner instructions and warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420367974650,"sku":"44629000","price":2263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL35-N7-MG-Marine-Grade-Radiant-Patio-Heater-Natural-Gas_34563__21209.1790133063.1280.1280.jpg?v=1795638617"},{"product_id":"sunstar-phj40-l6-standing-patio-heater-propane","title":"SunStar PHJ40-L6 Standing Patio Heater – Propane","description":"\u003cp\u003eSunStar PHJ40-L6 provides freestanding propane patio heat.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e40,000 BTU\/hr propane standing patio heater.\u003c\/li\u003e\n\u003cli\u003eHammertone jet black\/silver finish.\u003c\/li\u003e\n\u003cli\u003eOutdoor use only; do not operate in enclosed spaces.\u003c\/li\u003e\n\u003cli\u003ePiezo ignition; no electrical connection is needed.\u003c\/li\u003e\n\u003cli\u003eDesigned for a standard 20 lb propane cylinder; cylinder not included in this listing.\u003c\/li\u003e\n\u003cli\u003eWheels and four base cup holders are included.\u003c\/li\u003e\n\u003cli\u003eOverall height: 89 inches. Reflector diameter: 34 inches.\u003c\/li\u003e\n\u003cli\u003eMinimum clearance to combustible materials: 24 inches above and to the sides. Install on firm, level ground.\u003c\/li\u003e\n\u003cli\u003eShipping weight: 79 lb; product weight is 64 lb.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2023\/05\/Patio-Heater-P-101-071520.pdf\" rel=\"noopener\"\u003eProduct specification sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2020\/05\/44080000-IO-Patio-Heater-PHS40-PHJ40.pdf\" rel=\"noopener\"\u003eInstallation and owner manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2015\/07\/patio_warranty.pdf\" rel=\"noopener\"\u003eLimited warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420368007418,"sku":"44030500","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-PHJ40-L6-Standing-Patio-Heater-Propane_34554__14987.1790133045.1280.1280.jpg?v=1795638621"},{"product_id":"sunstar-sgl35-l10-mg-marine-grade-radiant-patio-heater-propane","title":"SunStar SGL35-L10-MG Marine-Grade Radiant Patio Heater – Propane","description":"\u003cp\u003eSGL35-L10-MG is a propane radiant patio heater with 316 stainless steel marine-grade housing.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e35,000 BTU\/hr high input and 24,000 BTU\/hr low input; propane model.\u003c\/li\u003e\n\u003cli\u003e316 stainless steel marine-grade housing.\u003c\/li\u003e\n\u003cli\u003eCeramic glass radiant heating with direct spark ignition.\u003c\/li\u003e\n\u003cli\u003eElectrical supply: 120V AC, 60 Hz, single phase, 0.4A. Gas connection: 1\/2-inch NPT male.\u003c\/li\u003e\n\u003cli\u003eOutdoor residential and commercial use. Indoor use is limited to approved commercial\/industrial applications; not for indoor residential dwellings.\u003c\/li\u003e\n\u003cli\u003eRemote handset, batteries and High\/Low\/Off switch are included with this N10\/L10 configuration.\u003c\/li\u003e\n\u003cli\u003eHeat shield and mounting hardware are separate accessories unless specified in the purchased kit.\u003c\/li\u003e\n\u003cli\u003eWithout a heat shield, horizontal outdoor minimum clearances are 22 inches above, 20 inches to the sides, 12 inches at ends and 40 inches below.\u003c\/li\u003e\n\u003cli\u003eAngled mounting, shield-equipped installations and indoor installations have different clearances. Follow the corresponding installation-manual diagrams.\u003c\/li\u003e\n\u003cli\u003eHanging centers: 48 inches. This is mounting spacing, not overall heater length.\u003c\/li\u003e\n\u003cli\u003eBody cross-section: 9.6 inches high by 11.8 inches. See the dimensional drawing for installation.\u003c\/li\u003e\n\u003cli\u003eShipping weight: 55 lb. Source carton dimensions: 15\" X 16\" X 57\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2022\/02\/MG-Patio-Heater-w-heatshield-R131.pdf\" rel=\"noopener\"\u003eBrochure \/ specification sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sunstarheaters.com\/wp-content\/uploads\/2022\/06\/44201540-IO-SGL-Series-Patio-Heater-MG-8-sided-rev-April-2022-A.pdf\" rel=\"noopener\"\u003eInstallation, owner instructions and warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420368040186,"sku":"44629050","price":2528.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL35-L10-MG-Marine-Grade-Radiant-Patio-Heater-Propane_34568__82173.1790133082.1280.1280.jpg?v=1795638625"},{"product_id":"sunstar-chain-kit-for-all-ceramic-heaters","title":"SunStar 12' Chain Kit For All Ceramic Heaters","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eThis chain kit is used to hang heaters from the ceiling. Includes 12' of chain and 8 S-hooks. For use with all ceramic heaters.\u003c\/span\u003e\u003cbr role=\"none\"\u003e\u003c\/p\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eChain Kit, 12 ft. chain with 8 hooks for indoor installations.\u003c\/li\u003e\n\u003cli\u003eTo be used for indoor installations\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003emade in USA.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"last\"\u003e\u003c\/ul\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e2.0 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e12\" L x 12\" W x 12\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420368138490,"sku":"41690120","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-12-Chain-Kit-for-All-Ceramic-Heaters.jpg?v=1795638630"},{"product_id":"sunstar-threaded-rod-suspension-bracket-for-infrared-patio-heaters","title":"SunStar Threaded Rod Suspension Bracket for Infrared Patio Heaters","description":"\u003cdiv data-mce-style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/sunstar-authorized-dealer-logo-480x480.png\" width=\"180\" height=\"180\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cspan\u003eThreaded Rod Suspension Bracket for 3\/8\" threaded rod suspension from the ceiling.\u003c\/span\u003e\u003cbr role=\"none\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTo be used for 3\/8\" threaded rod suspension from the ceiling.\u003c\/li\u003e\n\u003cli\u003eBlack Powder Coat Painted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"last\"\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"long data\" border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e2.0 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e12\" L x 12\" W x 12\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDownloads\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar_rod_suspension_assembly_instructions.pdf\"\u003eDownload Assembly Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420368204026,"sku":"44560354","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Threaded-Rod-Suspension-Bracket-for-Infrared-Patio-Heaters.jpg?v=1795638633"},{"product_id":"sunstar-column-mounting-arm-kit-for-infrared-patio-heaters","title":"SunStar Column Mounting Arm Kit For Infrared Patio Heaters","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eColumn Mounting Arm Kit - Suitable for columns 7\" and wider. Hardware included. \u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"last\"\u003e\u003c\/ul\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"0\" class=\"long data\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e6.0 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e17.0\" L x 9.0\" W x 7.0\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar_column_mounting_assembly_instructions.pdf\"\u003eDownload Assembly Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420368236794,"sku":"44560590","price":348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Column-Mounting-Arm-Kit-for-Infrared-Patio-Heaters.jpg?v=1795638637"},{"product_id":"sunstar-4-pole-mounting-bracket-kit-for-infrared-patio-heaters","title":"SunStar 4\" Pole Mounting Bracket Kit For Infrared Patio Heaters","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e4\" Pole Mounting Bracket Arm Kit (4\" pole not included). Hardware included.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e4\" Pole Mounting Arm Kit. (4\" pole not included)\u003c\/li\u003e\n\u003cli\u003eBlack Powder Coat Painted\u003c\/li\u003e\n\u003cli\u003eEnables for pole mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"last\"\u003e\u003c\/ul\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e15.0 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e49\" L x 9\" D x 9\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar_pole_mounting_assembly_instructions.pdf\"\u003eDownload Assembly Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420368269562,"sku":"44560609","price":247.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-4-Pole-Mounting-Bracket-Kit-for-Infrared-Patio-Heaters.jpg?v=1795638641"},{"product_id":"sunstar-heat-shield-kit-for-infrared-patio-heaters","title":"SunStar Heat Shield Kit For Infrared Patio Heaters","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eHeat Shield Kits reduce clearances to combustibles above to 10\" and allows the heater to reside closer to the ceiling. Allows for Horizontal and up to 60° installations. Hardware included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e*Note: \"It's a heat shield kit only, the heater is not included\".\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003cul class=\"last\"\u003e\n\u003cli\u003eHeat Shield Kit -to reduce Clearances to Combustibles above to 10\" and allows the heater to be installed closer to the ceiling\u003c\/li\u003e\n\u003cli\u003eBlack Powder Coat Painted\u003c\/li\u003e\n\u003cli\u003eInstalled for horizontal as well up to 60 degree installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e11.0 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e41.0\" L x 6.0\" W x 24.0\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420368302330,"sku":"44566300","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Heat-Shield-Kit-for-Infrared-Patio-Heaters.jpg?v=1795638644"},{"product_id":"sunstar-ceiling-fixed-mount-bracket-kit-for-infrared-patio-heaters","title":"SunStar Ceiling Fixed Mount Bracket Kit For Infrared Patio Heaters","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eCeiling Mount Bracket Kit - 10\" fixed installation for minimum overhead clearance. MUST be used with heat shield kit, when installed below a combustible ceiling. Hardware included.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003cul class=\"last\"\u003e\n\u003cli\u003eCeiling Mount Bracket Kit- 10\" fixed installation for minimum overhead clearance.\u003c\/li\u003e\n\u003cli\u003eBlack Powder Coat Painted\u003c\/li\u003e\n\u003cli\u003eAccessories Not Included: Heat Shield to reduce the clearances to combustibles above and enable to install the heater 10\" from the ceiling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e5.0 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e17.0\" L x 9.0\" W x 9.0\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420368367866,"sku":"44560353","price":63.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Ceiling-Fixed-Mount-Bracket-Kit-for-Infrared-Patio-Heaters.jpg?v=1795638648"},{"product_id":"sunstar-3-pole-mounting-arm-kit-for-infrared-patio-heaters","title":"SunStar 3\" Pole Mounting Arm Kit For Infrared Patio Heaters","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e3\" Pole Mounting Bracket Arm Kit (3\" pole not included). Hardware included.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e3\" Pole Mounting Arm Kit. (3\" pole not included)\u003c\/li\u003e\n\u003cli\u003eBlack Powder Coat Painted\u003c\/li\u003e\n\u003cli\u003eEnables for pole mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"last\"\u003e\u003c\/ul\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e15.0 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e49\" L x 9\" D x 9\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar_pole_mounting_assembly_instructions.pdf\"\u003eDownload Assembly Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420369350906,"sku":"44560600","price":272.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-3-Pole-Mounting-Arm-Kit-for-Infrared-Patio-Heaters.jpg?v=1795638652"},{"product_id":"sunstar-gas-line-pressure-regulator-up-to-2-psig-for-infrared-heaters","title":"SunStar Gas Line Pressure Regulator Up To 2 PSIG For Infrared Heaters","description":"\u003cp\u003e\u003cstrong\u003eSunStar products are made to \u003c\/strong\u003e\u003cstrong\u003eorder. Estimated lead time is 4-6 Weeks.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eThis Regulator is for use with all Tube Heaters between 1\/2 and 2 psig. The maximum supply pressure to the infrared heaters is 14\" WC or 1\/2 psig. If your supply pressure is between 1\/2 psig and 2 psig then you will need this second stage regulator. The regulator is equipped with vent limiting device and complies with ANSI standards. The regulator does not need any venting. This product has limited warranty of 1 year. This product is made in USA.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003cul class=\"last\"\u003e\n\u003cli\u003eDurable, corrosion-resistant construction\u003c\/li\u003e\n\u003cli\u003eEquipped with 12A09 Vent Limiting Device\u003c\/li\u003e\n\u003cli\u003eIn the event of diaphragm rupture, gas escapement is limited to a non-hazardous level\u003c\/li\u003e\n\u003cli\u003eMust be installed on a horizontal plane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"0\" class=\"long data\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e2.0 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420369383674,"sku":"03307260","price":79.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Gas-Line-Pressure-Regulator-Up-To-2-PSIG-for-Infrared-Heaters.jpg?v=1795638656"},{"product_id":"sunstar-two-stage-economy-thermostat-for-infrared-patio-heaters","title":"SunStar Two Stage Economy Thermostat for Infrared Patio Heaters","description":"\u003cdiv data-mce-style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/sunstar-authorized-dealer-logo-480x480.png\" width=\"180\" height=\"180\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo Stage Economy Thermostat for indoor applications. \u003c\/span\u003e\u003cspan\u003e24V, temperature range 50° to 90°F (∓4°F differential). Up to 85 operating humidity range (%RH). Manual changeover\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cul\u003e\n\u003cli\u003eEconomy two stage thermostat\u003c\/li\u003e\n\u003cli\u003eTo be used for indoor applications\u003c\/li\u003e\n\u003cli\u003eTemperature range of 50 to 90 degrees Fahrenheit \u003cspan data-mce-fragment=\"1\"\u003e(±4°F differential)\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420369547514,"sku":"30348100","price":74.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Two-Stage-Economy-Thermostat-for-Infrared-Patio-Heaters.jpg?v=1795638660"},{"product_id":"sunstar-gas-connection-kit-for-infrared-patio-heaters","title":"SunStar Gas Connection Kit For Infrared Patio Heaters","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eGas Connection Kit- 1\/2in.-Includes Gas Connector, Manual Ball Valve, Sediment Trap (Tee, Cap, Nipple), Thread Sealing Compound.\u003c\/p\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e2.0 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan class=\"keyspectype\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e12.0\" L x 6.0\" W x 12.0\" H \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420369580282,"sku":"44604510","price":63.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Gas-Connection-Kit-for-Infrared-Patio-Heaters.jpg?v=1795638663"},{"product_id":"sunstar-two-stage-digital-thermostat-for-infrared-patio-heaters","title":"SunStar Two Stage Digital Thermostat for Infrared Patio Heaters","description":"\u003cdiv data-mce-style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/sunstar-authorized-dealer-logo-480x480.png\" width=\"180\" height=\"180\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cspan\u003eTwo Stage Digital Setback Thermostat for indoor applications. \u003c\/span\u003e\u003cspan\u003e7 - day programmable digital 24V thermostat, temperature range 40° to 90°F (∓1°F differential). Up to 85 operating humidity range (%RH). Automatic changeover\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cul\u003e\n\u003cli\u003e24V operation\u003c\/li\u003e\n\u003cli\u003e7-day programmable digital thermostat\u003c\/li\u003e\n\u003cli\u003e40º to 90ºF temperature range\u003c\/li\u003e\n\u003cli\u003e+\/- 1ºF differential\u003c\/li\u003e\n\u003cli\u003eControls 1 heater\u003c\/li\u003e\n\u003cli\u003eCan be used with Two Stage Relay Kit (44195000) to control multiple heaters with single thermostat - one relay kit required per heater\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFor modulating two stage heaters- N7 or L7 Control\u003c\/li\u003e\n\u003cli\u003e24V Digital Night Setback Thermostat with Large hybrid dot matrix display \u003c\/li\u003e\n\u003cli\u003eTemporary override, Hold \u0026amp; Vacation hold\u003c\/li\u003e\n\u003cli\u003eOptional smart recovery\u003c\/li\u003e\n\u003cli\u003eAdvanced copy function for fast easy programming\u003c\/li\u003e\n\u003cli\u003eProgrammable length minimum run time\u003c\/li\u003e\n\u003cli\u003eMulti-stage adjustable temperature differential\/cycle rate ± 2.25ºF differential\u003c\/li\u003e\n\u003cli\u003eMultimode keyboard lockout with user programmable 3 Digit Code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420370268410,"sku":"30644100","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Two-Stage-Digital-Thermostat-for-Infrared-Patio-Heaters.jpg?v=1795638667"},{"product_id":"sunstar-heat-shield-kit-for-sgl50-infrared-patio-heaters","title":"SunStar Heat Shield Kit For SGL50 Infrared Patio Heaters","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eHeat Shield Kits reduce clearances to combustibles above to 10\" and allows the heater to reside closer to the ceiling. Allows for Horizontal and up to 60° installations. Hardware included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e*Note: \"It's a heat shield kit only, the heater is not included\".\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"last\"\u003e\n\u003cli\u003eHeat Shield Kit -to reduce Clearances to Combustibles above to 10\" and allows the heater to be installed closer to the ceiling\u003c\/li\u003e\n\u003cli\u003eBlack Powder Coat Painted\u003c\/li\u003e\n\u003cli\u003eInstalled for horizontal as well up to 60 degree installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"0\" class=\"long data\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e1 year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e11.0 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"50%\"\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e\u003cspan\u003e41.0\" L x 6.0\" W x 24.0\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420370301178,"sku":"44566400","price":330.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Heat-Shield-Kit-for-Infrared-Patio-Heaters_a8e7289f-1c4b-4c1e-aeb2-42a7039b5f69.jpg?v=1795638670"},{"product_id":"sunstar-two-stage-thermostat-relay-kit-for-infrared-patio-heaters","title":"SunStar Two Stage Thermostat Relay Kit for Infrared Patio Heaters","description":"\u003cp\u003e\u003cstrong\u003eSunStar products are made to \u003c\/strong\u003e\u003cstrong\u003eorder. Estimated lead time is 4-6 Weeks.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTwo Stage Relay Kit for controlling multiple heaters with a single 3 position switch or single 24V Two Stage thermostat. Waterproof ABS Construction. Up to 85 operating humidity range (%RH).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eTwo stage relay kit\u003c\/li\u003e\n\u003cli\u003eOne per heater required\u003c\/li\u003e\n\u003cli\u003eControls multiple heaters with a single 24V thermostat\u003c\/li\u003e\n\u003cli\u003eWaterproof ABS Construction\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420370366714,"sku":"44195000","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Two-Stage-Thermostat-Relay-Kit-for-Infrared-Patio-Heaters.jpg?v=1795638675"},{"product_id":"sunstar-sgl-glass-series-48-50000-btu-hr-black-infrared-patio-heater-with-propane-gas","title":"SunStar SGL Glass Series 48\" 50000 BTU\/hr Black Infrared Patio Heater With Propane Gas","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eLike the radiant warmth from the sun, radiant heat warms people and objects directly at ﬂoor level without ﬁrst heating the surrounding air. Customers can dine and relax under the radiant warmth of the GLASS, and help you to maximize the use of your seating areas during those colder winter months. Designed with high temperature tinted glass, SunStar GLASS is wind resistant up to 40MPH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFactory shipped as a two stage control heater and can be used with optional 3 position switch or optional remote control for ultimate comfort. Operate at ﬁrst stage (as low as 24,000 BTU\/hr) during milder days and operated at full power (as high as 50,000 BTU\/hr) on colder days. Also it can be operated at full power (up to 50,000 BTU\/hr) as a single stage heater by a simple factory supplied jumper wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eWhat's Included\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-Stage 34,000 TO 50,000 BTU Infrared Heater\u003c\/li\u003e\n\u003cli\u003eCeramic Glass 10.50” x 48” Black \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSunStar Clearances sign\u003c\/li\u003e\n\u003cli\u003eAngle Mounting Gauge Plate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot Included \u003cem\u003e(Sold Separately)\u003c\/em\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e3 Position Switch Kit (High\/Low\/Off)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo Stage Thermostat Relay Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStainless Steel Gas Connector\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Connection Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Line Pressure Regulator Up To 2 PSIG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeat Shield Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCeiling Fixed Mount Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e15\"-22\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e15\"-30\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eColumn Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e3\" Pole Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e4\" Pole Mounting Bracket Kit \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e12\" Chain Kit\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eOptional 2-Stage Remote Control Available\u003c\/li\u003e\n\u003cli\u003eOutdoor rated.\u003c\/li\u003e\n\u003cli\u003eCan be mounted from horizontal position to 60°.\u003c\/li\u003e\n\u003cli\u003eTwo-stage (high \/ low) models.\u003c\/li\u003e\n\u003cli\u003eAvailable for natural gas and LPG.\u003c\/li\u003e\n\u003cli\u003eChain suspension or wall mounted.\u003c\/li\u003e\n\u003cli\u003eAesthetically designed with glass front to blend with nearly any decor.\u003c\/li\u003e\n\u003cli\u003eCSA Design Certiﬁed -Z83.19 \u0026amp; Z83.26\u003c\/li\u003e\n\u003cli\u003eDesigned for restaurants, residential patios and other hospitality service industries, SunStar GLASS is wind resistant up to 40MPH.\u003c\/li\u003e\n\u003cli\u003eHigh temperature tinted glass provides additional protection on windy days and enhances heater’s aesthetic appeal.\u003c\/li\u003e\n\u003cli\u003eThe SunStar GLASS radiant patio heater is ideal for out door or partially covered dining areas, bars, patios, verandas, smoking areas, vestibules and other outdoor areas.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eClearances above can be as low as 10” with optional heat shield\u003c\/li\u003e\n\u003cli\u003eCovers 12’ by 12’ area with minimal wind conditions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003ePropane Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eDirect Spark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eChain Suspension Or Wall\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eCoverage Area\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e144 ft²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e11.5\" D x 48\" W x 9.5\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e55 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBTU Ratings (BTU\/hr)\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh\u003c\/strong\u003e - 50,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e Low\u003c\/strong\u003e - 34,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003e\n\u003cspan\u003eMounting Height\u003c\/span\u003e\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-11' horizontal; 7'-9' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eSpace Between Heaters\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-16' horizontal; 6'-14' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBurner Pressure\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNG\u003c\/strong\u003e - 6.0\" w.c.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLP \u003c\/strong\u003e- \u003cspan\u003e11.0\" W.C.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003eDimensions\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_SGL35-N7_Dimensions-480x480.jpg\" width=\"450\" height=\"450\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003eSGL Clearance to Combustibles\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Angle\u003c\/th\u003e\n\u003cth\u003eCeiling\u003c\/th\u003e\n\u003cth\u003eCeiling*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003cth\u003eBack*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30°\u003c\/td\u003e\n\u003ctd\u003e23\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSide\u003c\/th\u003e\n\u003cth\u003eEnd\u003c\/th\u003e\n\u003cth\u003eBelow\u003c\/th\u003e\n\u003cth\u003eFront\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e*Note: \u003c\/strong\u003e\u003cem\u003e\"Installed w\/optional clearance shield to reduce ceiling \u0026amp; back clearances\u003c\/em\u003e\u003cem\u003e\".\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch1\u003eWarranty\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/1-year_Warranty_Badge_feda9a11-bab7-4ab1-aa50-200fd2fb004d.jpg\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e1-year limited manufacturer warranty on controls\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/3-year_Warranty_Badge.jpg\" width=\"100%\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e3-year limited manufacturer warranty on the burner assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-IO-SGL-Series-Glass-Patio-Heater-rev-Mar-2019-Manual.pdf\"\u003eInstallation and Owner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-R130-SGL-Series-Patio-Heater-Specs.pdf\"\u003eSpecs Sheet\u003cbr\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-Heater-Sizing-Layout-Guidelines.pdf\"\u003e\u003cspan\u003eSizing \u0026amp; Layout Guidelines\u003c\/span\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_patio_heater_comparisons.pdf\"\u003e\u003cspan\u003eSGL Series Patio Heater Comparison\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_accessories.pdf\"\u003e\u003cspan\u003eSGL Series Glass Patio Heater Accessories\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878760-SGL-Patio-Heater-Column-Mounting-IO.pdf\"\u003e\u003cspan\u003eSGL Glass Series - Column Mounting I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878770-SGL-Patio-Heater-Rod-Suspension-IO.pdf\"\u003e\u003cspan\u003eSGL Glass Series - Rod Suspension I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/44201630-Form-Retrofit-Remote-Control-SUNSTAR.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series Retrofit – Remote Control Form\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhy is a SunStar infrared radiant gas heater more efficient than unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003eThe major difference between a gas-fired infrared heating system and a forced hot air heating system is the method used to create a comfortable temperature. Infrared heats the floor slab, the machinery and the people first and then the air by using all three methods of heat transfer: radiation, conduction and convection. The storage of the heat in the slab floor creates a low temperature emitter and a faster recovery time when large overhead doors are opened and closed.With a forced air system, the hot air rises to the ceiling and stratifies, gradually working its way down to thermostat level so that the floor slab never becomes warm enough to be comfortable. It literally acts as a heat sink, draining heat from the air and from personnel standing on the floor. The ceiling area of a high bay building using a forced air system can be easily 30° to 40° warmer than the floor area. In the same type building heated with an infrared system, the temperature is much more uniform and the loft or roof area usually will be at a slightly lower temperature than the floor level… a good condition for minimizing heat loss. Comfort can be maintained with a lower air temperature that will reduce infiltration and heat loss through the walls and roof.In addition, instead of adding Btu\/hr capacity to a computed building heat loss based on the thermal efficiency of a forced air system, the capacity is normally reduced by as much as 15%. An added plus is that an infrared system has minimal power requirements, needing electricity only for burner ignition, the gas valve and the draft inducer (where applicable).It is, therefore, easy to understand that infrared commonly can save 30% to 50% in energy costs over unit heaters, frequently even more.\u003c\/summary\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow do you size infrared when replacing existing forced air unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003cp\u003eAn infrared heating system is always sized at a lower input capacity when compared to forced air (convection) heating. This is due to different modes of heat transfer (radiation vs. convection), thermal mass and minimal stratification between ceiling and floor temperatures. For retrofit purposes, provided the unit heaters are maintaining the desired inside design temperature at ASHRAe design conditions, the following reduction can be utilized when recommending an infrared heating system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eThermal Efficiency\u003c\/th\u003e\n\u003cth\u003e% Reduction in System Sizing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Efficiency Unit Heater\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003e32%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvectional Unit Heater\u003c\/td\u003e\n\u003ctd\u003e62%\u003c\/td\u003e\n\u003ctd\u003e48%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAssuming that the ASHRAE heat loss for a building is 100,000 Btu\/hr, then the heater selection for this building would be as follows:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eInfrared Heater\u003c\/th\u003e\n\u003cth\u003eUnit Heater\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor\u003cbr\u003e(for radiant heating)\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Efficiency\u003cbr\u003e(for convection heating)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Input Required\u003c\/td\u003e\n\u003ctd\u003e85,000 Btu\/hr\u003cbr\u003e(100,000 x 0.85)\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003cbr\u003e(100,000 \/ 0.80)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWouldn’t it be more efficient to use unvented heaters so heat wouldn’t be lost out the flue?\u003c\/strong\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eNo. The National Fuel Gas Code (NFPA54) and local codes require a minimum ventilation flow of 4 CFM per 1000 Btu\/hr of heater input by either mechanical or gravity ventilation if the heaters themselves are not vented to the outside. This additional ventilation requirement increases the building heat loss and the fuel cost as indicated in this example:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Differential (inside temp less outside design temp)\u003c\/td\u003e\n\u003ctd\u003e65° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor (based on 16′ mounting height)\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Heat Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eVented\u003c\/th\u003e\n\u003cth\u003eUnvented\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ventilation Required:\u003c\/td\u003e\n\u003ctd\u003e0 CFM\u003c\/td\u003e\n\u003ctd\u003e4 CFM per 1000 Btu\/hr = 400 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Loss Due to Ventilation\u003c\/td\u003e\n\u003ctd\u003e0 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003eQ = CFM x 60 min\/hr x TD x 0.018 400x60x65°x0.018=28,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Input Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e128,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow many square feet does a SunStar infrared radiant gas heater cover?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eThe heater model and capacity are not necessarily a function of the square footage of the area needing to be heated. The model generally is chosen after the Btu\/hr heat loss for the building or spot area to be heated has been determined, which is a function of not only the size of the area, but geographic location, building materials, building usage and other factors. Area coverage could be as little as 500 sq. ft for residential garage heaters or as much as 10,000 sq. ft. for a large commercial size heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eAre there applications for which SunStar radiant gas heaters are NOT suitable?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eYou may not use gas-fired infrared heaters inside paint booths or in buildings where explosion-proof lights are required. Although infrared is not ideal as an air curtain, it is very effective in spot-heating work areas inside of doorways, in dock areas and on outdoor docks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow low can i hang my SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eSunStar infrared heaters have been mounted as low as 8′ above the finished floor (in home garages and workshops) to as high as 70′ (in high bay aircraft hangars). The mounting height depends on the Btu\/hr capacity and model of the heater. Please refer to the heater’s specification sheet for minimum recommended mounting height and required clearances to combustible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat extra items are needed for installation?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eDepending on your particular application, you will want to consider the following six accessories for all series of SunStar infrared tube heaters:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eThermostat\u003c\/li\u003e\n\u003cli\u003eManual Cutoff Valve\u003c\/li\u003e\n\u003cli\u003eFlexible Gas Connector (Included as part of the SunStar tube heaters)\u003c\/li\u003e\n\u003cli\u003eSecond Stage Regulator if supply pressure is over 14″ W.C.\u003c\/li\u003e\n\u003cli\u003eVent Cap\u003c\/li\u003e\n\u003cli\u003eChain Kit with S hooks for hanging heater.\u003c\/li\u003e\n\u003cli\u003eEnd Reflector Kit for SIS \u0026amp; SPS Series ( optional, but recommended).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SIU Series, also consider including two additional accessories:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTwo End Reflector Kits per heater ( optional, but recommended)\u003c\/li\u003e\n\u003cli\u003eU-Bend reflector (optional, but recommended)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SG and SGM ceramic heaters, you will not need a vent cap.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow are SunStar infrared radiant gas heaters controlled?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003ePrimarily, the heater is controlled by a line voltage thermostat. Alternatively, you may use a 24-volt thermostat with a relay kit or an on\/off switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is a “TOUGH GUY” Heater?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eTOUGH GUY Emitter tubes use heat-treated aluminized steel tubes that that can withstand higher operating temperatures than other conventional tube materials and is very absorptive of the flame on the inside of the tube and very emissive on the outside, increasing the heating efficiency. The heat treating process provides unsurpassed corrosion resistance to ferrous metal by providing a self-forming, self-healing coating of practically infusible alumina which is impervious to oxygen, carbon, sulfur and the products of combustion of natural and liquefied propane gas and is, therefore, extremely corrosion resistant. TOUGH GUY emitter tubes are highly recommended for high humidity \/ corrosive environments such as dairy barns, swimming pools, greenhouses, or water treatment plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have UL certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eBecause our infrared gas heaters are gas appliances, it is not necessary that they be listed by UL (a nationally recognized testing laboratory – NRTL); however, all of the electrical component parts are UL listed (e.g., the draft inducer motors, which are equipped with CSA and UL approved thermal protectors). Our heaters are certified by C.S.A. (a nationally recognized testing laboratory – NRTL) and carry the C.S.A. seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20 for infrared heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have FM certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eGenerally, Factory Mutual certification (a nationally recognized testing laboratory – NRTL) is applicable to products that cannot be certified at the manufacturer’s facility according to American National Standard and, therefore, need to be certified at the installation site. Our heaters are certified by C.S.A.(a nationally recognized testing laboratory – NRTL) and carry the CSA seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20. Factory Mutual recognizes International Approval Services certification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat are the emission levels of SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eAir-free CO emission levels are 0.0010 – 0.0020%, or 20 to 40 times lower than the maximum acceptable level as indicated in American National Standard Z83.20. SunStar utilizes burners that are made of heavy duty cast iron and are designed to enhance maximum primary and secondary air flow around the venturi assembly. The high velocity of the flame and the delayed flame-quench period minimize the products of combustion which include aldehyde, formic acid, nitrous oxide, and carbon monoxide.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420371251450,"sku":"SGL50-L7","price":2154.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL-Glass-Series-48-35000-BTUhr-Black-Infrared-Patio-Heater-With-Natural-Gas_b820fdd6-5682-4148-b3a2-f65520e633c1.jpg?v=1795638681"},{"product_id":"sunstar-3-position-switch-kit-high-low-off-for-manual-heater-control","title":"SunStar 3 Position Switch Kit (High\/Low\/Off) for Manual Heater Control","description":"\u003cp\u003e\u003cstrong\u003eSunStar products are made to \u003c\/strong\u003e\u003cstrong\u003eorder. Estimated lead time is 4-6 Weeks.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eThis SunStar 3 Position Switch Kit is high-quality, well-engineered, and ready to stand the test of time. Warm up and breathe easy, thanks to Sunstar.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e3 position switch kit\u003c\/li\u003e\n\u003cli\u003eComes with high\/low\/off switch\u003c\/li\u003e\n\u003cli\u003eFor manual control of two stage heaters\u003c\/li\u003e\n\u003cli\u003eWaterproof ABS Construction\u003c\/li\u003e\n\u003cli\u003eOutdoor rated\u003c\/li\u003e\n\u003cli\u003eOne Switch Per Heater\u003c\/li\u003e\n\u003cli\u003eFor multiple heaters to be controlled by a single switch\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eCA Residents: \u003c\/strong\u003e\u003cspan\u003eSee Prop 65\u003c\/span\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\"\u003eWARNING\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420371284218,"sku":"40147031","price":76.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-3-Position-Switch-Kit-HighLowOff-for-Manual-Heater-Control_470ca282.jpg?v=1795638684"},{"product_id":"sunstar-single-switch-controller-with-built-in-solid-state","title":"SunStar Single Switch Controller with Built-In Solid State","description":"\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\n\u003csection class=\"left-side alternate-view\"\u003e\n\u003cdiv class=\"product-desc\"\u003e\u003cspan\u003eThis 24 Volt relay kit is to be used with a 24 Volt thermostat in conjunction with one straight or u-shaped infrared tube heater. \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/section\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e24V Relay Kit (SIR Series), to be used with 24V Thermostat (#30562000), one per heater.\u003c\/li\u003e\n\u003cli\u003eMade in USA\u003c\/li\u003e\n\u003cli\u003eUL Listed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"last\"\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420371316986,"sku":"44610550","price":352.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-Single-Switch-Controller-with-Built-In-Solid-State.jpg?v=1795638688"},{"product_id":"sunstar-sgl-glass-series-48-50000-btu-hr-black-infrared-patio-heater-with-natural-gas-and-remote","title":"SunStar SGL Glass Series 48\" 50000 BTU\/hr Black Infrared Patio Heater With Natural Gas And Remote","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eLike the radiant warmth from the sun, radiant heat warms people and objects directly at ﬂoor level without ﬁrst heating the surrounding air. Customers can dine and relax under the radiant warmth of the GLASS, and help you to maximize the use of your seating areas during those colder winter months. Designed with high temperature tinted glass, SunStar GLASS is wind resistant up to 40MPH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFactory shipped as a two stage control heater and can be used with optional 3 position switch or optional remote control for ultimate comfort. Operate at ﬁrst stage (as low as 24,000 BTU\/hr) during milder days and operated at full power (as high as 50,000 BTU\/hr) on colder days. Also it can be operated at full power (up to 50,000 BTU\/hr) as a single stage heater by a simple factory supplied jumper wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eWhat's Included\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-Stage 34,000 TO 50,000 BTU Infrared Heater \u003c\/li\u003e\n\u003cli\u003eCeramic Glass 10.50” x 48” Black \u003c\/li\u003e\n\u003cli\u003eSunStar Clearances sign\u003c\/li\u003e\n\u003cli\u003eAngle Mounting Gauge Plate\u003c\/li\u003e\n\u003cli\u003eRemote 2-stage Sunstar\u003c\/li\u003e\n\u003cli\u003eAAA Battery 2 Pack\u003c\/li\u003e\n\u003cli\u003e3 Position Switch Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot Included \u003cem\u003e(Sold Separately)\u003c\/em\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo Stage Thermostat Relay Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStainless Steel Gas Connector\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Connection Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Line Pressure Regulator Up To 2 PSIG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeat Shield Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCeiling Fixed Mount Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e15\"-22\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e15\"-30\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eColumn Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e3\" Pole Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e4\" Pole Mounting Bracket Kit \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e12\" Chain Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eOptional 2-Stage Remote Control Available\u003c\/li\u003e\n\u003cli\u003eOutdoor rated.\u003c\/li\u003e\n\u003cli\u003eCan be mounted from horizontal position to 60°.\u003c\/li\u003e\n\u003cli\u003eTwo-stage (high \/ low) models.\u003c\/li\u003e\n\u003cli\u003eAvailable for natural gas and LPG.\u003c\/li\u003e\n\u003cli\u003eChain suspension or wall mounted.\u003c\/li\u003e\n\u003cli\u003eAesthetically designed with glass front to blend with nearly any decor.\u003c\/li\u003e\n\u003cli\u003eCSA Design Certiﬁed -Z83.19 \u0026amp; Z83.26\u003c\/li\u003e\n\u003cli\u003eDesigned for restaurants, residential patios and other hospitality service industries, SunStar GLASS is wind resistant up to 40MPH.\u003c\/li\u003e\n\u003cli\u003eHigh temperature tinted glass provides additional protection on windy days and enhances heater’s aesthetic appeal.\u003c\/li\u003e\n\u003cli\u003eThe SunStar GLASS radiant patio heater is ideal for out door or partially covered dining areas, bars, patios, verandas, smoking areas, vestibules and other outdoor areas.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eClearances above can be as low as 10” with optional heat shield\u003c\/li\u003e\n\u003cli\u003eCovers 12’ by 12’ area with minimal wind conditions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eDirect Spark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eChain Suspension Or Wall\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eCoverage Area\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e144 ft²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e11.5\" D x 48\" W x 9.5\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e55 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBTU Ratings (BTU\/hr)\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh\u003c\/strong\u003e - 50,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e Low\u003c\/strong\u003e - 34,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003e\n\u003cspan\u003eMounting Height\u003c\/span\u003e\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-11' horizontal; 7'-9' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eSpace Between Heaters\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-16' horizontal; 6'-14' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBurner Pressure\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNG\u003c\/strong\u003e - 6.0\" w.c.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLP \u003c\/strong\u003e- \u003cspan\u003e11.0\" W.C.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003eDimensions\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_SGL35-N7_Dimensions-480x480.jpg\" width=\"450\" height=\"450\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003eSGL Clearance to Combustibles\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Angle\u003c\/th\u003e\n\u003cth\u003eCeiling\u003c\/th\u003e\n\u003cth\u003eCeiling*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003cth\u003eBack*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30°\u003c\/td\u003e\n\u003ctd\u003e23\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSide\u003c\/th\u003e\n\u003cth\u003eEnd\u003c\/th\u003e\n\u003cth\u003eBelow\u003c\/th\u003e\n\u003cth\u003eFront\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e*Note: \u003c\/strong\u003e\u003cem\u003e\"Installed w\/optional clearance shield to reduce ceiling \u0026amp; back clearances\u003c\/em\u003e\u003cem\u003e\".\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch1\u003eWarranty\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/1-year_Warranty_Badge_feda9a11-bab7-4ab1-aa50-200fd2fb004d.jpg\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e1-year limited manufacturer warranty on controls\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg width=\"100%\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/3-year_Warranty_Badge.jpg\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e3-year limited manufacturer warranty on the burner assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-IO-SGL-Series-Glass-Patio-Heater-rev-Mar-2019-Manual.pdf\"\u003eInstallation and Owner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-R130-SGL-Series-Patio-Heater-Specs.pdf\"\u003eSpecs Sheet\u003cbr\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-Heater-Sizing-Layout-Guidelines.pdf\"\u003e\u003cspan\u003eSizing \u0026amp; Layout Guidelines\u003c\/span\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_patio_heater_comparisons.pdf\"\u003e\u003cspan\u003eSGL Series Patio Heater Comparison\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_accessories.pdf\"\u003e\u003cspan\u003eSGL Series Glass Patio Heater Accessories\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878760-SGL-Patio-Heater-Column-Mounting-IO.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series - Column Mounting I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878770-SGL-Patio-Heater-Rod-Suspension-IO.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series - Rod Suspension I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/44201630-Form-Retrofit-Remote-Control-SUNSTAR.pdf\"\u003e\u003cspan\u003eSGL Glass Series Retrofit – Remote Control Form\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhy is a SunStar infrared radiant gas heater more efficient than unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003eThe major difference between a gas-fired infrared heating system and a forced hot air heating system is the method used to create a comfortable temperature. Infrared heats the floor slab, the machinery and the people first and then the air by using all three methods of heat transfer: radiation, conduction and convection. The storage of the heat in the slab floor creates a low temperature emitter and a faster recovery time when large overhead doors are opened and closed.With a forced air system, the hot air rises to the ceiling and stratifies, gradually working its way down to thermostat level so that the floor slab never becomes warm enough to be comfortable. It literally acts as a heat sink, draining heat from the air and from personnel standing on the floor. The ceiling area of a high bay building using a forced air system can be easily 30° to 40° warmer than the floor area. In the same type building heated with an infrared system, the temperature is much more uniform and the loft or roof area usually will be at a slightly lower temperature than the floor level… a good condition for minimizing heat loss. Comfort can be maintained with a lower air temperature that will reduce infiltration and heat loss through the walls and roof.In addition, instead of adding Btu\/hr capacity to a computed building heat loss based on the thermal efficiency of a forced air system, the capacity is normally reduced by as much as 15%. An added plus is that an infrared system has minimal power requirements, needing electricity only for burner ignition, the gas valve and the draft inducer (where applicable).It is, therefore, easy to understand that infrared commonly can save 30% to 50% in energy costs over unit heaters, frequently even more.\u003c\/summary\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow do you size infrared when replacing existing forced air unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003cp\u003eAn infrared heating system is always sized at a lower input capacity when compared to forced air (convection) heating. This is due to different modes of heat transfer (radiation vs. convection), thermal mass and minimal stratification between ceiling and floor temperatures. For retrofit purposes, provided the unit heaters are maintaining the desired inside design temperature at ASHRAe design conditions, the following reduction can be utilized when recommending an infrared heating system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eThermal Efficiency\u003c\/th\u003e\n\u003cth\u003e% Reduction in System Sizing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Efficiency Unit Heater\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003e32%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvectional Unit Heater\u003c\/td\u003e\n\u003ctd\u003e62%\u003c\/td\u003e\n\u003ctd\u003e48%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAssuming that the ASHRAE heat loss for a building is 100,000 Btu\/hr, then the heater selection for this building would be as follows:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eInfrared Heater\u003c\/th\u003e\n\u003cth\u003eUnit Heater\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor\u003cbr\u003e(for radiant heating)\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Efficiency\u003cbr\u003e(for convection heating)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Input Required\u003c\/td\u003e\n\u003ctd\u003e85,000 Btu\/hr\u003cbr\u003e(100,000 x 0.85)\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003cbr\u003e(100,000 \/ 0.80)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWouldn’t it be more efficient to use unvented heaters so heat wouldn’t be lost out the flue?\u003c\/strong\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eNo. The National Fuel Gas Code (NFPA54) and local codes require a minimum ventilation flow of 4 CFM per 1000 Btu\/hr of heater input by either mechanical or gravity ventilation if the heaters themselves are not vented to the outside. This additional ventilation requirement increases the building heat loss and the fuel cost as indicated in this example:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Differential (inside temp less outside design temp)\u003c\/td\u003e\n\u003ctd\u003e65° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor (based on 16′ mounting height)\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Heat Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eVented\u003c\/th\u003e\n\u003cth\u003eUnvented\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ventilation Required:\u003c\/td\u003e\n\u003ctd\u003e0 CFM\u003c\/td\u003e\n\u003ctd\u003e4 CFM per 1000 Btu\/hr = 400 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Loss Due to Ventilation\u003c\/td\u003e\n\u003ctd\u003e0 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003eQ = CFM x 60 min\/hr x TD x 0.018 400x60x65°x0.018=28,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Input Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e128,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow many square feet does a SunStar infrared radiant gas heater cover?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eThe heater model and capacity are not necessarily a function of the square footage of the area needing to be heated. The model generally is chosen after the Btu\/hr heat loss for the building or spot area to be heated has been determined, which is a function of not only the size of the area, but geographic location, building materials, building usage and other factors. Area coverage could be as little as 500 sq. ft for residential garage heaters or as much as 10,000 sq. ft. for a large commercial size heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eAre there applications for which SunStar radiant gas heaters are NOT suitable?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eYou may not use gas-fired infrared heaters inside paint booths or in buildings where explosion-proof lights are required. Although infrared is not ideal as an air curtain, it is very effective in spot-heating work areas inside of doorways, in dock areas and on outdoor docks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow low can i hang my SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eSunStar infrared heaters have been mounted as low as 8′ above the finished floor (in home garages and workshops) to as high as 70′ (in high bay aircraft hangars). The mounting height depends on the Btu\/hr capacity and model of the heater. Please refer to the heater’s specification sheet for minimum recommended mounting height and required clearances to combustible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat extra items are needed for installation?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eDepending on your particular application, you will want to consider the following six accessories for all series of SunStar infrared tube heaters:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eThermostat\u003c\/li\u003e\n\u003cli\u003eManual Cutoff Valve\u003c\/li\u003e\n\u003cli\u003eFlexible Gas Connector (Included as part of the SunStar tube heaters)\u003c\/li\u003e\n\u003cli\u003eSecond Stage Regulator if supply pressure is over 14″ W.C.\u003c\/li\u003e\n\u003cli\u003eVent Cap\u003c\/li\u003e\n\u003cli\u003eChain Kit with S hooks for hanging heater.\u003c\/li\u003e\n\u003cli\u003eEnd Reflector Kit for SIS \u0026amp; SPS Series ( optional, but recommended).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SIU Series, also consider including two additional accessories:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTwo End Reflector Kits per heater ( optional, but recommended)\u003c\/li\u003e\n\u003cli\u003eU-Bend reflector (optional, but recommended)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SG and SGM ceramic heaters, you will not need a vent cap.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow are SunStar infrared radiant gas heaters controlled?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003ePrimarily, the heater is controlled by a line voltage thermostat. Alternatively, you may use a 24-volt thermostat with a relay kit or an on\/off switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is a “TOUGH GUY” Heater?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eTOUGH GUY Emitter tubes use heat-treated aluminized steel tubes that that can withstand higher operating temperatures than other conventional tube materials and is very absorptive of the flame on the inside of the tube and very emissive on the outside, increasing the heating efficiency. The heat treating process provides unsurpassed corrosion resistance to ferrous metal by providing a self-forming, self-healing coating of practically infusible alumina which is impervious to oxygen, carbon, sulfur and the products of combustion of natural and liquefied propane gas and is, therefore, extremely corrosion resistant. TOUGH GUY emitter tubes are highly recommended for high humidity \/ corrosive environments such as dairy barns, swimming pools, greenhouses, or water treatment plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have UL certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eBecause our infrared gas heaters are gas appliances, it is not necessary that they be listed by UL (a nationally recognized testing laboratory – NRTL); however, all of the electrical component parts are UL listed (e.g., the draft inducer motors, which are equipped with CSA and UL approved thermal protectors). Our heaters are certified by C.S.A. (a nationally recognized testing laboratory – NRTL) and carry the C.S.A. seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20 for infrared heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have FM certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eGenerally, Factory Mutual certification (a nationally recognized testing laboratory – NRTL) is applicable to products that cannot be certified at the manufacturer’s facility according to American National Standard and, therefore, need to be certified at the installation site. Our heaters are certified by C.S.A.(a nationally recognized testing laboratory – NRTL) and carry the CSA seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20. Factory Mutual recognizes International Approval Services certification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat are the emission levels of SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eAir-free CO emission levels are 0.0010 – 0.0020%, or 20 to 40 times lower than the maximum acceptable level as indicated in American National Standard Z83.20. SunStar utilizes burners that are made of heavy duty cast iron and are designed to enhance maximum primary and secondary air flow around the venturi assembly. The high velocity of the flame and the delayed flame-quench period minimize the products of combustion which include aldehyde, formic acid, nitrous oxide, and carbon monoxide.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420371611898,"sku":"SGL50-N10","price":2464.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL-Glass-Series-48-35000-BTUhr-Black-Infrared-Patio-Heater-With-Natural-Gas_5e33184c-0185-4e84-bd53-9ca74919c33c.jpg?v=1795638692"},{"product_id":"sunstar-sgl-glass-series-48-50000-btu-hr-black-infrared-patio-heater-with-propane-gas-and-remote","title":"SunStar SGL Glass Series 48\" 50000 BTU\/hr Black Infrared Patio Heater With Propane Gas And Remote","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eLike the radiant warmth from the sun, radiant heat warms people and objects directly at ﬂoor level without ﬁrst heating the surrounding air. Customers can dine and relax under the radiant warmth of the GLASS, and help you to maximize the use of your seating areas during those colder winter months. Designed with high temperature tinted glass, SunStar GLASS is wind resistant up to 40MPH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFactory shipped as a two stage control heater and can be used with optional 3 position switch or optional remote control for ultimate comfort. Operate at ﬁrst stage (as low as 24,000 BTU\/hr) during milder days and operated at full power (as high as 50,000 BTU\/hr) on colder days. Also it can be operated at full power (up to 50,000 BTU\/hr) as a single stage heater by a simple factory supplied jumper wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eWhat's Included\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-Stage 34,000 TO 50,000 BTU Infrared Heater\u003c\/li\u003e\n\u003cli\u003eCeramic Glass 10.50” x 48” Black \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSunStar Clearances sign\u003c\/li\u003e\n\u003cli\u003eAngle Mounting Gauge Plate\u003c\/li\u003e\n\u003cli\u003eRemote 2-stage Sunstar\u003c\/li\u003e\n\u003cli\u003eAAA Battery 2 Pack\u003c\/li\u003e\n\u003cli\u003e3 Position Switch Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot Included \u003cem\u003e(Sold Separately)\u003c\/em\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo Stage Thermostat Relay Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStainless Steel Gas Connector\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Connection Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Line Pressure Regulator Up To 2 PSIG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeat Shield Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCeiling Fixed Mount Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e15\"-22\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e15\"-30\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eColumn Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e3\" Pole Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e4\" Pole Mounting Bracket Kit \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e12\" Chain Kit\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eOptional 2-Stage Remote Control Available\u003c\/li\u003e\n\u003cli\u003eOutdoor rated.\u003c\/li\u003e\n\u003cli\u003eCan be mounted from horizontal position to 60°.\u003c\/li\u003e\n\u003cli\u003eTwo-stage (high \/ low) models.\u003c\/li\u003e\n\u003cli\u003eAvailable for natural gas and LPG.\u003c\/li\u003e\n\u003cli\u003eChain suspension or wall mounted.\u003c\/li\u003e\n\u003cli\u003eAesthetically designed with glass front to blend with nearly any decor.\u003c\/li\u003e\n\u003cli\u003eCSA Design Certiﬁed -Z83.19 \u0026amp; Z83.26\u003c\/li\u003e\n\u003cli\u003eDesigned for restaurants, residential patios and other hospitality service industries, SunStar GLASS is wind resistant up to 40MPH.\u003c\/li\u003e\n\u003cli\u003eHigh temperature tinted glass provides additional protection on windy days and enhances heater’s aesthetic appeal.\u003c\/li\u003e\n\u003cli\u003eThe SunStar GLASS radiant patio heater is ideal for out door or partially covered dining areas, bars, patios, verandas, smoking areas, vestibules and other outdoor areas.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eClearances above can be as low as 10” with optional heat shield\u003c\/li\u003e\n\u003cli\u003eCovers 12’ by 12’ area with minimal wind conditions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003ePropane Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eDirect Spark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eChain Suspension Or Wall\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eCoverage Area\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e144 ft²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e11.5\" D x 48\" W x 9.5\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e55 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBTU Ratings (BTU\/hr)\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh\u003c\/strong\u003e - 50,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e Low\u003c\/strong\u003e - 34,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003e\n\u003cspan\u003eMounting Height\u003c\/span\u003e\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-11' horizontal; 7'-9' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eSpace Between Heaters\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-16' horizontal; 6'-14' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBurner Pressure\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNG\u003c\/strong\u003e - 6.0\" w.c.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLP \u003c\/strong\u003e- \u003cspan\u003e11.0\" W.C.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003eDimensions\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_SGL35-N7_Dimensions-480x480.jpg\" width=\"450\" height=\"450\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003eSGL Clearance to Combustibles\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Angle\u003c\/th\u003e\n\u003cth\u003eCeiling\u003c\/th\u003e\n\u003cth\u003eCeiling*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003cth\u003eBack*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30°\u003c\/td\u003e\n\u003ctd\u003e23\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSide\u003c\/th\u003e\n\u003cth\u003eEnd\u003c\/th\u003e\n\u003cth\u003eBelow\u003c\/th\u003e\n\u003cth\u003eFront\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e*Note: \u003c\/strong\u003e\u003cem\u003e\"Installed w\/optional clearance shield to reduce ceiling \u0026amp; back clearances\u003c\/em\u003e\u003cem\u003e\".\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch1\u003eWarranty\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/1-year_Warranty_Badge_feda9a11-bab7-4ab1-aa50-200fd2fb004d.jpg\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e1-year limited manufacturer warranty on controls\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/3-year_Warranty_Badge.jpg\" width=\"100%\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e3-year limited manufacturer warranty on the burner assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-IO-SGL-Series-Glass-Patio-Heater-rev-Mar-2019-Manual.pdf\"\u003eInstallation and Owner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-R130-SGL-Series-Patio-Heater-Specs.pdf\"\u003eSpecs Sheet\u003cbr\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-Heater-Sizing-Layout-Guidelines.pdf\"\u003e\u003cspan\u003eSizing \u0026amp; Layout Guidelines\u003c\/span\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_patio_heater_comparisons.pdf\"\u003e\u003cspan\u003eSGL Series Patio Heater Comparison\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_accessories.pdf\"\u003e\u003cspan\u003eSGL Series Glass Patio Heater Accessories\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878760-SGL-Patio-Heater-Column-Mounting-IO.pdf\"\u003e\u003cspan\u003eSGL Glass Series - Column Mounting I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878770-SGL-Patio-Heater-Rod-Suspension-IO.pdf\"\u003e\u003cspan\u003eSGL Glass Series - Rod Suspension I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/44201630-Form-Retrofit-Remote-Control-SUNSTAR.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series Retrofit – Remote Control Form\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhy is a SunStar infrared radiant gas heater more efficient than unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003eThe major difference between a gas-fired infrared heating system and a forced hot air heating system is the method used to create a comfortable temperature. Infrared heats the floor slab, the machinery and the people first and then the air by using all three methods of heat transfer: radiation, conduction and convection. The storage of the heat in the slab floor creates a low temperature emitter and a faster recovery time when large overhead doors are opened and closed.With a forced air system, the hot air rises to the ceiling and stratifies, gradually working its way down to thermostat level so that the floor slab never becomes warm enough to be comfortable. It literally acts as a heat sink, draining heat from the air and from personnel standing on the floor. The ceiling area of a high bay building using a forced air system can be easily 30° to 40° warmer than the floor area. In the same type building heated with an infrared system, the temperature is much more uniform and the loft or roof area usually will be at a slightly lower temperature than the floor level… a good condition for minimizing heat loss. Comfort can be maintained with a lower air temperature that will reduce infiltration and heat loss through the walls and roof.In addition, instead of adding Btu\/hr capacity to a computed building heat loss based on the thermal efficiency of a forced air system, the capacity is normally reduced by as much as 15%. An added plus is that an infrared system has minimal power requirements, needing electricity only for burner ignition, the gas valve and the draft inducer (where applicable).It is, therefore, easy to understand that infrared commonly can save 30% to 50% in energy costs over unit heaters, frequently even more.\u003c\/summary\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow do you size infrared when replacing existing forced air unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003cp\u003eAn infrared heating system is always sized at a lower input capacity when compared to forced air (convection) heating. This is due to different modes of heat transfer (radiation vs. convection), thermal mass and minimal stratification between ceiling and floor temperatures. For retrofit purposes, provided the unit heaters are maintaining the desired inside design temperature at ASHRAe design conditions, the following reduction can be utilized when recommending an infrared heating system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eThermal Efficiency\u003c\/th\u003e\n\u003cth\u003e% Reduction in System Sizing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Efficiency Unit Heater\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003e32%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvectional Unit Heater\u003c\/td\u003e\n\u003ctd\u003e62%\u003c\/td\u003e\n\u003ctd\u003e48%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAssuming that the ASHRAE heat loss for a building is 100,000 Btu\/hr, then the heater selection for this building would be as follows:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eInfrared Heater\u003c\/th\u003e\n\u003cth\u003eUnit Heater\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor\u003cbr\u003e(for radiant heating)\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Efficiency\u003cbr\u003e(for convection heating)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Input Required\u003c\/td\u003e\n\u003ctd\u003e85,000 Btu\/hr\u003cbr\u003e(100,000 x 0.85)\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003cbr\u003e(100,000 \/ 0.80)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWouldn’t it be more efficient to use unvented heaters so heat wouldn’t be lost out the flue?\u003c\/strong\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eNo. The National Fuel Gas Code (NFPA54) and local codes require a minimum ventilation flow of 4 CFM per 1000 Btu\/hr of heater input by either mechanical or gravity ventilation if the heaters themselves are not vented to the outside. This additional ventilation requirement increases the building heat loss and the fuel cost as indicated in this example:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Differential (inside temp less outside design temp)\u003c\/td\u003e\n\u003ctd\u003e65° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor (based on 16′ mounting height)\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Heat Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eVented\u003c\/th\u003e\n\u003cth\u003eUnvented\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ventilation Required:\u003c\/td\u003e\n\u003ctd\u003e0 CFM\u003c\/td\u003e\n\u003ctd\u003e4 CFM per 1000 Btu\/hr = 400 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Loss Due to Ventilation\u003c\/td\u003e\n\u003ctd\u003e0 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003eQ = CFM x 60 min\/hr x TD x 0.018 400x60x65°x0.018=28,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Input Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e128,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow many square feet does a SunStar infrared radiant gas heater cover?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eThe heater model and capacity are not necessarily a function of the square footage of the area needing to be heated. The model generally is chosen after the Btu\/hr heat loss for the building or spot area to be heated has been determined, which is a function of not only the size of the area, but geographic location, building materials, building usage and other factors. Area coverage could be as little as 500 sq. ft for residential garage heaters or as much as 10,000 sq. ft. for a large commercial size heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eAre there applications for which SunStar radiant gas heaters are NOT suitable?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eYou may not use gas-fired infrared heaters inside paint booths or in buildings where explosion-proof lights are required. Although infrared is not ideal as an air curtain, it is very effective in spot-heating work areas inside of doorways, in dock areas and on outdoor docks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow low can i hang my SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eSunStar infrared heaters have been mounted as low as 8′ above the finished floor (in home garages and workshops) to as high as 70′ (in high bay aircraft hangars). The mounting height depends on the Btu\/hr capacity and model of the heater. Please refer to the heater’s specification sheet for minimum recommended mounting height and required clearances to combustible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat extra items are needed for installation?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eDepending on your particular application, you will want to consider the following six accessories for all series of SunStar infrared tube heaters:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eThermostat\u003c\/li\u003e\n\u003cli\u003eManual Cutoff Valve\u003c\/li\u003e\n\u003cli\u003eFlexible Gas Connector (Included as part of the SunStar tube heaters)\u003c\/li\u003e\n\u003cli\u003eSecond Stage Regulator if supply pressure is over 14″ W.C.\u003c\/li\u003e\n\u003cli\u003eVent Cap\u003c\/li\u003e\n\u003cli\u003eChain Kit with S hooks for hanging heater.\u003c\/li\u003e\n\u003cli\u003eEnd Reflector Kit for SIS \u0026amp; SPS Series ( optional, but recommended).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SIU Series, also consider including two additional accessories:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTwo End Reflector Kits per heater ( optional, but recommended)\u003c\/li\u003e\n\u003cli\u003eU-Bend reflector (optional, but recommended)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SG and SGM ceramic heaters, you will not need a vent cap.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow are SunStar infrared radiant gas heaters controlled?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003ePrimarily, the heater is controlled by a line voltage thermostat. Alternatively, you may use a 24-volt thermostat with a relay kit or an on\/off switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is a “TOUGH GUY” Heater?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eTOUGH GUY Emitter tubes use heat-treated aluminized steel tubes that that can withstand higher operating temperatures than other conventional tube materials and is very absorptive of the flame on the inside of the tube and very emissive on the outside, increasing the heating efficiency. The heat treating process provides unsurpassed corrosion resistance to ferrous metal by providing a self-forming, self-healing coating of practically infusible alumina which is impervious to oxygen, carbon, sulfur and the products of combustion of natural and liquefied propane gas and is, therefore, extremely corrosion resistant. TOUGH GUY emitter tubes are highly recommended for high humidity \/ corrosive environments such as dairy barns, swimming pools, greenhouses, or water treatment plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have UL certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eBecause our infrared gas heaters are gas appliances, it is not necessary that they be listed by UL (a nationally recognized testing laboratory – NRTL); however, all of the electrical component parts are UL listed (e.g., the draft inducer motors, which are equipped with CSA and UL approved thermal protectors). Our heaters are certified by C.S.A. (a nationally recognized testing laboratory – NRTL) and carry the C.S.A. seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20 for infrared heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have FM certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eGenerally, Factory Mutual certification (a nationally recognized testing laboratory – NRTL) is applicable to products that cannot be certified at the manufacturer’s facility according to American National Standard and, therefore, need to be certified at the installation site. Our heaters are certified by C.S.A.(a nationally recognized testing laboratory – NRTL) and carry the CSA seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20. Factory Mutual recognizes International Approval Services certification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat are the emission levels of SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eAir-free CO emission levels are 0.0010 – 0.0020%, or 20 to 40 times lower than the maximum acceptable level as indicated in American National Standard Z83.20. SunStar utilizes burners that are made of heavy duty cast iron and are designed to enhance maximum primary and secondary air flow around the venturi assembly. The high velocity of the flame and the delayed flame-quench period minimize the products of combustion which include aldehyde, formic acid, nitrous oxide, and carbon monoxide.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420372168954,"sku":"SGL50-L10","price":2464.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL-Glass-Series-48-35000-BTUhr-Black-Infrared-Patio-Heater-With-Natural-Gas_37599c91-012f-4c36-84fb-f684bf1a7213.jpg?v=1795638698"},{"product_id":"sunstar-sgl-glass-series-48-50000-btu-hr-black-infrared-patio-heater-with-natural-gas","title":"SunStar SGL Glass Series 48\" 50000 BTU\/hr Black Infrared Patio Heater With Natural Gas","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eLike the radiant warmth from the sun, radiant heat warms people and objects directly at ﬂoor level without ﬁrst heating the surrounding air. Customers can dine and relax under the radiant warmth of the GLASS, and help you to maximize the use of your seating areas during those colder winter months. Designed with high temperature tinted glass, SunStar GLASS is wind resistant up to 40MPH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFactory shipped as a two stage control heater and can be used with optional 3 position switch or optional remote control for ultimate comfort. Operate at ﬁrst stage (as low as 24,000 BTU\/hr) during milder days and operated at full power (as high as 50,000 BTU\/hr) on colder days. Also it can be operated at full power (up to 50,000 BTU\/hr) as a single stage heater by a simple factory supplied jumper wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eWhat's Included\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-Stage 34,000 TO 50,000 BTU Infrared Heater \u003c\/li\u003e\n\u003cli\u003eCeramic Glass 10.50” x 48” Black \u003c\/li\u003e\n\u003cli\u003eSunStar Clearances sign\u003c\/li\u003e\n\u003cli\u003eAngle Mounting Gauge Plate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot Included \u003cem\u003e(Sold Separately)\u003c\/em\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e3 Position Switch Kit (High\/Low\/Off)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo Stage Thermostat Relay Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStainless Steel Gas Connector\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Connection Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Line Pressure Regulator Up To 2 PSIG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeat Shield Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCeiling Fixed Mount Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e15\"-22\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e15\"-30\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eColumn Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e3\" Pole Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e4\" Pole Mounting Bracket Kit \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e12\" Chain Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eOptional 2-Stage Remote Control Available\u003c\/li\u003e\n\u003cli\u003eOutdoor rated.\u003c\/li\u003e\n\u003cli\u003eCan be mounted from horizontal position to 60°.\u003c\/li\u003e\n\u003cli\u003eTwo-stage (high \/ low) models.\u003c\/li\u003e\n\u003cli\u003eAvailable for natural gas and LPG.\u003c\/li\u003e\n\u003cli\u003eChain suspension or wall mounted.\u003c\/li\u003e\n\u003cli\u003eAesthetically designed with glass front to blend with nearly any decor.\u003c\/li\u003e\n\u003cli\u003eCSA Design Certiﬁed -Z83.19 \u0026amp; Z83.26\u003c\/li\u003e\n\u003cli\u003eDesigned for restaurants, residential patios and other hospitality service industries, SunStar GLASS is wind resistant up to 40MPH.\u003c\/li\u003e\n\u003cli\u003eHigh temperature tinted glass provides additional protection on windy days and enhances heater’s aesthetic appeal.\u003c\/li\u003e\n\u003cli\u003eThe SunStar GLASS radiant patio heater is ideal for out door or partially covered dining areas, bars, patios, verandas, smoking areas, vestibules and other outdoor areas.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eClearances above can be as low as 10” with optional heat shield\u003c\/li\u003e\n\u003cli\u003eCovers 12’ by 12’ area with minimal wind conditions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eDirect Spark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eChain Suspension Or Wall\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eCoverage Area\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e144 ft²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e11.5\" D x 48\" W x 9.5\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e55 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBTU Ratings (BTU\/hr)\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh\u003c\/strong\u003e - 50,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e Low\u003c\/strong\u003e - 34,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003e\n\u003cspan\u003eMounting Height\u003c\/span\u003e\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-11' horizontal; 7'-9' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eSpace Between Heaters\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-16' horizontal; 6'-14' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBurner Pressure\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNG\u003c\/strong\u003e - 6.0\" w.c.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLP \u003c\/strong\u003e- \u003cspan\u003e11.0\" W.C.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003eDimensions\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_SGL35-N7_Dimensions-480x480.jpg\" width=\"450\" height=\"450\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003eSGL Clearance to Combustibles\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Angle\u003c\/th\u003e\n\u003cth\u003eCeiling\u003c\/th\u003e\n\u003cth\u003eCeiling*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003cth\u003eBack*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30°\u003c\/td\u003e\n\u003ctd\u003e23\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSide\u003c\/th\u003e\n\u003cth\u003eEnd\u003c\/th\u003e\n\u003cth\u003eBelow\u003c\/th\u003e\n\u003cth\u003eFront\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e*Note: \u003c\/strong\u003e\u003cem\u003e\"Installed w\/optional clearance shield to reduce ceiling \u0026amp; back clearances\u003c\/em\u003e\u003cem\u003e\".\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch1\u003eWarranty\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/1-year_Warranty_Badge_feda9a11-bab7-4ab1-aa50-200fd2fb004d.jpg\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e1-year limited manufacturer warranty on controls\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg width=\"100%\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/3-year_Warranty_Badge.jpg\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e3-year limited manufacturer warranty on the burner assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-IO-SGL-Series-Glass-Patio-Heater-rev-Mar-2019-Manual.pdf\"\u003eInstallation and Owner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-R130-SGL-Series-Patio-Heater-Specs.pdf\"\u003eSpecs Sheet\u003cbr\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-Heater-Sizing-Layout-Guidelines.pdf\"\u003e\u003cspan\u003eSizing \u0026amp; Layout Guidelines\u003c\/span\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_patio_heater_comparisons.pdf\"\u003e\u003cspan\u003eSGL Series Patio Heater Comparison\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_accessories.pdf\"\u003e\u003cspan\u003eSGL Series Glass Patio Heater Accessories\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878760-SGL-Patio-Heater-Column-Mounting-IO.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series - Column Mounting I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878770-SGL-Patio-Heater-Rod-Suspension-IO.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series - Rod Suspension I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/44201630-Form-Retrofit-Remote-Control-SUNSTAR.pdf\"\u003e\u003cspan\u003eSGL Glass Series Retrofit – Remote Control Form\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhy is a SunStar infrared radiant gas heater more efficient than unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003eThe major difference between a gas-fired infrared heating system and a forced hot air heating system is the method used to create a comfortable temperature. Infrared heats the floor slab, the machinery and the people first and then the air by using all three methods of heat transfer: radiation, conduction and convection. The storage of the heat in the slab floor creates a low temperature emitter and a faster recovery time when large overhead doors are opened and closed.With a forced air system, the hot air rises to the ceiling and stratifies, gradually working its way down to thermostat level so that the floor slab never becomes warm enough to be comfortable. It literally acts as a heat sink, draining heat from the air and from personnel standing on the floor. The ceiling area of a high bay building using a forced air system can be easily 30° to 40° warmer than the floor area. In the same type building heated with an infrared system, the temperature is much more uniform and the loft or roof area usually will be at a slightly lower temperature than the floor level… a good condition for minimizing heat loss. Comfort can be maintained with a lower air temperature that will reduce infiltration and heat loss through the walls and roof.In addition, instead of adding Btu\/hr capacity to a computed building heat loss based on the thermal efficiency of a forced air system, the capacity is normally reduced by as much as 15%. An added plus is that an infrared system has minimal power requirements, needing electricity only for burner ignition, the gas valve and the draft inducer (where applicable).It is, therefore, easy to understand that infrared commonly can save 30% to 50% in energy costs over unit heaters, frequently even more.\u003c\/summary\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow do you size infrared when replacing existing forced air unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003cp\u003eAn infrared heating system is always sized at a lower input capacity when compared to forced air (convection) heating. This is due to different modes of heat transfer (radiation vs. convection), thermal mass and minimal stratification between ceiling and floor temperatures. For retrofit purposes, provided the unit heaters are maintaining the desired inside design temperature at ASHRAe design conditions, the following reduction can be utilized when recommending an infrared heating system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eThermal Efficiency\u003c\/th\u003e\n\u003cth\u003e% Reduction in System Sizing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Efficiency Unit Heater\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003e32%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvectional Unit Heater\u003c\/td\u003e\n\u003ctd\u003e62%\u003c\/td\u003e\n\u003ctd\u003e48%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAssuming that the ASHRAE heat loss for a building is 100,000 Btu\/hr, then the heater selection for this building would be as follows:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eInfrared Heater\u003c\/th\u003e\n\u003cth\u003eUnit Heater\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor\u003cbr\u003e(for radiant heating)\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Efficiency\u003cbr\u003e(for convection heating)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Input Required\u003c\/td\u003e\n\u003ctd\u003e85,000 Btu\/hr\u003cbr\u003e(100,000 x 0.85)\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003cbr\u003e(100,000 \/ 0.80)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWouldn’t it be more efficient to use unvented heaters so heat wouldn’t be lost out the flue?\u003c\/strong\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eNo. The National Fuel Gas Code (NFPA54) and local codes require a minimum ventilation flow of 4 CFM per 1000 Btu\/hr of heater input by either mechanical or gravity ventilation if the heaters themselves are not vented to the outside. This additional ventilation requirement increases the building heat loss and the fuel cost as indicated in this example:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Differential (inside temp less outside design temp)\u003c\/td\u003e\n\u003ctd\u003e65° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor (based on 16′ mounting height)\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Heat Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eVented\u003c\/th\u003e\n\u003cth\u003eUnvented\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ventilation Required:\u003c\/td\u003e\n\u003ctd\u003e0 CFM\u003c\/td\u003e\n\u003ctd\u003e4 CFM per 1000 Btu\/hr = 400 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Loss Due to Ventilation\u003c\/td\u003e\n\u003ctd\u003e0 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003eQ = CFM x 60 min\/hr x TD x 0.018 400x60x65°x0.018=28,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Input Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e128,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow many square feet does a SunStar infrared radiant gas heater cover?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eThe heater model and capacity are not necessarily a function of the square footage of the area needing to be heated. The model generally is chosen after the Btu\/hr heat loss for the building or spot area to be heated has been determined, which is a function of not only the size of the area, but geographic location, building materials, building usage and other factors. Area coverage could be as little as 500 sq. ft for residential garage heaters or as much as 10,000 sq. ft. for a large commercial size heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eAre there applications for which SunStar radiant gas heaters are NOT suitable?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eYou may not use gas-fired infrared heaters inside paint booths or in buildings where explosion-proof lights are required. Although infrared is not ideal as an air curtain, it is very effective in spot-heating work areas inside of doorways, in dock areas and on outdoor docks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow low can i hang my SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eSunStar infrared heaters have been mounted as low as 8′ above the finished floor (in home garages and workshops) to as high as 70′ (in high bay aircraft hangars). The mounting height depends on the Btu\/hr capacity and model of the heater. Please refer to the heater’s specification sheet for minimum recommended mounting height and required clearances to combustible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat extra items are needed for installation?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eDepending on your particular application, you will want to consider the following six accessories for all series of SunStar infrared tube heaters:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eThermostat\u003c\/li\u003e\n\u003cli\u003eManual Cutoff Valve\u003c\/li\u003e\n\u003cli\u003eFlexible Gas Connector (Included as part of the SunStar tube heaters)\u003c\/li\u003e\n\u003cli\u003eSecond Stage Regulator if supply pressure is over 14″ W.C.\u003c\/li\u003e\n\u003cli\u003eVent Cap\u003c\/li\u003e\n\u003cli\u003eChain Kit with S hooks for hanging heater.\u003c\/li\u003e\n\u003cli\u003eEnd Reflector Kit for SIS \u0026amp; SPS Series ( optional, but recommended).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SIU Series, also consider including two additional accessories:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTwo End Reflector Kits per heater ( optional, but recommended)\u003c\/li\u003e\n\u003cli\u003eU-Bend reflector (optional, but recommended)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SG and SGM ceramic heaters, you will not need a vent cap.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow are SunStar infrared radiant gas heaters controlled?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003ePrimarily, the heater is controlled by a line voltage thermostat. Alternatively, you may use a 24-volt thermostat with a relay kit or an on\/off switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is a “TOUGH GUY” Heater?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eTOUGH GUY Emitter tubes use heat-treated aluminized steel tubes that that can withstand higher operating temperatures than other conventional tube materials and is very absorptive of the flame on the inside of the tube and very emissive on the outside, increasing the heating efficiency. The heat treating process provides unsurpassed corrosion resistance to ferrous metal by providing a self-forming, self-healing coating of practically infusible alumina which is impervious to oxygen, carbon, sulfur and the products of combustion of natural and liquefied propane gas and is, therefore, extremely corrosion resistant. TOUGH GUY emitter tubes are highly recommended for high humidity \/ corrosive environments such as dairy barns, swimming pools, greenhouses, or water treatment plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have UL certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eBecause our infrared gas heaters are gas appliances, it is not necessary that they be listed by UL (a nationally recognized testing laboratory – NRTL); however, all of the electrical component parts are UL listed (e.g., the draft inducer motors, which are equipped with CSA and UL approved thermal protectors). Our heaters are certified by C.S.A. (a nationally recognized testing laboratory – NRTL) and carry the C.S.A. seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20 for infrared heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have FM certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eGenerally, Factory Mutual certification (a nationally recognized testing laboratory – NRTL) is applicable to products that cannot be certified at the manufacturer’s facility according to American National Standard and, therefore, need to be certified at the installation site. Our heaters are certified by C.S.A.(a nationally recognized testing laboratory – NRTL) and carry the CSA seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20. Factory Mutual recognizes International Approval Services certification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat are the emission levels of SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eAir-free CO emission levels are 0.0010 – 0.0020%, or 20 to 40 times lower than the maximum acceptable level as indicated in American National Standard Z83.20. SunStar utilizes burners that are made of heavy duty cast iron and are designed to enhance maximum primary and secondary air flow around the venturi assembly. The high velocity of the flame and the delayed flame-quench period minimize the products of combustion which include aldehyde, formic acid, nitrous oxide, and carbon monoxide.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420372201722,"sku":"SGL50-N7","price":2154.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL-Glass-Series-48-35000-BTUhr-Black-Infrared-Patio-Heater-With-Natural-Gas_d13ccffd-5766-4b84-8fd9-5632e7383cdc.jpg?v=1795638702"},{"product_id":"sunstar-sgl-glass-series-48-35000-btu-hr-black-infrared-patio-heater-with-natural-gas-and-remote","title":"SunStar SGL Glass Series 48\" 35000 BTU\/hr Black Infrared Patio Heater With Natural Gas And Remote","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eLike the radiant warmth from the sun, radiant heat warms people and objects directly at ﬂoor level without ﬁrst heating the surrounding air. Customers can dine and relax under the radiant warmth of the GLASS, and help you to maximize the use of your seating areas during those colder winter months. Designed with high temperature tinted glass, SunStar GLASS is wind resistant up to 40MPH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFactory shipped as a two stage control heater and can be used with optional 3 position switch or optional remote control for ultimate comfort. Operate at ﬁrst stage (as low as 24,000 BTU\/hr) during milder days and operated at full power (as high as 50,000 BTU\/hr) on colder days. Also it can be operated at full power (up to 50,000 BTU\/hr) as a single stage heater by a simple factory supplied jumper wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eWhat's Included\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-Stage 35,000 TO 24,000 BTU Infrared Heater\u003c\/li\u003e\n\u003cli\u003eCeramic Glass 8.94” x 48” Black\u003c\/li\u003e\n\u003cli\u003eSunStar Clearances sign\u003c\/li\u003e\n\u003cli\u003eAngle Mounting Gauge Plate\u003c\/li\u003e\n\u003cli\u003eRemote 2-stage Sunstar\u003c\/li\u003e\n\u003cli\u003eAAA Battery 2 Pack \u003c\/li\u003e\n\u003cli\u003e3 Position Switch Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot Included \u003cem\u003e(Sold Separately)\u003c\/em\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo Stage Thermostat Relay Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStainless Steel Gas Connector\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Connection Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Line Pressure Regulator Up To 2 PSIG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeat Shield Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCeiling Fixed Mount Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e15\"-22\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e15\"-30\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eColumn Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e3\" Pole Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e4\" Pole Mounting Bracket Kit \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e12\" Chain Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eOptional 2-Stage Remote Control Available\u003c\/li\u003e\n\u003cli\u003eOutdoor rated.\u003c\/li\u003e\n\u003cli\u003eCan be mounted from horizontal position to 60°.\u003c\/li\u003e\n\u003cli\u003eTwo-stage (high \/ low) models.\u003c\/li\u003e\n\u003cli\u003eAvailable for natural gas and LPG.\u003c\/li\u003e\n\u003cli\u003eChain suspension or wall mounted.\u003c\/li\u003e\n\u003cli\u003eAesthetically designed with glass front to blend with nearly any decor.\u003c\/li\u003e\n\u003cli\u003eCSA Design Certiﬁed -Z83.19 \u0026amp; Z83.26\u003c\/li\u003e\n\u003cli\u003eDesigned for restaurants, residential patios and other hospitality service industries, SunStar GLASS is wind resistant up to 40MPH.\u003c\/li\u003e\n\u003cli\u003eHigh temperature tinted glass provides additional protection on windy days and enhances heater’s aesthetic appeal.\u003c\/li\u003e\n\u003cli\u003eThe SunStar GLASS radiant patio heater is ideal for out door or partially covered dining areas, bars, patios, verandas, smoking areas, vestibules and other outdoor areas.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eClearances above can be as low as 10” with optional heat shield\u003c\/li\u003e\n\u003cli\u003eCovers 12’ by 12’ area with minimal wind conditions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eDirect Spark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eChain Suspension Or Wall\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eCoverage Area\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e144 ft²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e11.5\" D x 48\" W x 9.5\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e55 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBTU Ratings (BTU\/hr)\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh\u003c\/strong\u003e - 35,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e Low\u003c\/strong\u003e - 24,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003e\n\u003cspan\u003eMounting Height\u003c\/span\u003e\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-11' horizontal; 7'-9' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eSpace Between Heaters\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-16' horizontal; 6'-14' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBurner Pressure\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNG\u003c\/strong\u003e - 6.0\" w.c.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLP \u003c\/strong\u003e- \u003cspan\u003e11.0\" W.C.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003eDimensions\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_SGL35-N7_Dimensions-480x480.jpg\" width=\"450\" height=\"450\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003eSGL Clearance to Combustibles\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Angle\u003c\/th\u003e\n\u003cth\u003eCeiling\u003c\/th\u003e\n\u003cth\u003eCeiling*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003cth\u003eBack*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30°\u003c\/td\u003e\n\u003ctd\u003e23\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSide\u003c\/th\u003e\n\u003cth\u003eEnd\u003c\/th\u003e\n\u003cth\u003eBelow\u003c\/th\u003e\n\u003cth\u003eFront\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e*Note: \u003c\/strong\u003e\u003cem\u003e\"Installed w\/optional clearance shield to reduce ceiling \u0026amp; back clearances\u003c\/em\u003e\u003cem\u003e\".\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch1\u003eWarranty\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/1-year_Warranty_Badge_feda9a11-bab7-4ab1-aa50-200fd2fb004d.jpg\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e1-year limited manufacturer warranty on controls\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg width=\"100%\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/3-year_Warranty_Badge.jpg\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e3-year limited manufacturer warranty on the burner assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-IO-SGL-Series-Glass-Patio-Heater-rev-Mar-2019-Manual.pdf\"\u003eInstallation and Owner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-R130-SGL-Series-Patio-Heater-Specs.pdf\"\u003eSpecs Sheet\u003cbr\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-Heater-Sizing-Layout-Guidelines.pdf\"\u003e\u003cspan\u003eSizing \u0026amp; Layout Guidelines\u003c\/span\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_patio_heater_comparisons.pdf\"\u003e\u003cspan\u003eSGL Series Patio Heater Comparison\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_accessories.pdf\"\u003e\u003cspan\u003eSGL Series Glass Patio Heater Accessories\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878760-SGL-Patio-Heater-Column-Mounting-IO.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series - Column Mounting I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878770-SGL-Patio-Heater-Rod-Suspension-IO.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series - Rod Suspension I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/44201630-Form-Retrofit-Remote-Control-SUNSTAR.pdf\"\u003e\u003cspan\u003eSGL Glass Series Retrofit – Remote Control Form\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhy is a SunStar infrared radiant gas heater more efficient than unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003eThe major difference between a gas-fired infrared heating system and a forced hot air heating system is the method used to create a comfortable temperature. Infrared heats the floor slab, the machinery and the people first and then the air by using all three methods of heat transfer: radiation, conduction and convection. The storage of the heat in the slab floor creates a low temperature emitter and a faster recovery time when large overhead doors are opened and closed.With a forced air system, the hot air rises to the ceiling and stratifies, gradually working its way down to thermostat level so that the floor slab never becomes warm enough to be comfortable. It literally acts as a heat sink, draining heat from the air and from personnel standing on the floor. The ceiling area of a high bay building using a forced air system can be easily 30° to 40° warmer than the floor area. In the same type building heated with an infrared system, the temperature is much more uniform and the loft or roof area usually will be at a slightly lower temperature than the floor level… a good condition for minimizing heat loss. Comfort can be maintained with a lower air temperature that will reduce infiltration and heat loss through the walls and roof.In addition, instead of adding Btu\/hr capacity to a computed building heat loss based on the thermal efficiency of a forced air system, the capacity is normally reduced by as much as 15%. An added plus is that an infrared system has minimal power requirements, needing electricity only for burner ignition, the gas valve and the draft inducer (where applicable).It is, therefore, easy to understand that infrared commonly can save 30% to 50% in energy costs over unit heaters, frequently even more.\u003c\/summary\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow do you size infrared when replacing existing forced air unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003cp\u003eAn infrared heating system is always sized at a lower input capacity when compared to forced air (convection) heating. This is due to different modes of heat transfer (radiation vs. convection), thermal mass and minimal stratification between ceiling and floor temperatures. For retrofit purposes, provided the unit heaters are maintaining the desired inside design temperature at ASHRAe design conditions, the following reduction can be utilized when recommending an infrared heating system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eThermal Efficiency\u003c\/th\u003e\n\u003cth\u003e% Reduction in System Sizing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Efficiency Unit Heater\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003e32%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvectional Unit Heater\u003c\/td\u003e\n\u003ctd\u003e62%\u003c\/td\u003e\n\u003ctd\u003e48%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAssuming that the ASHRAE heat loss for a building is 100,000 Btu\/hr, then the heater selection for this building would be as follows:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eInfrared Heater\u003c\/th\u003e\n\u003cth\u003eUnit Heater\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor\u003cbr\u003e(for radiant heating)\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Efficiency\u003cbr\u003e(for convection heating)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Input Required\u003c\/td\u003e\n\u003ctd\u003e85,000 Btu\/hr\u003cbr\u003e(100,000 x 0.85)\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003cbr\u003e(100,000 \/ 0.80)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWouldn’t it be more efficient to use unvented heaters so heat wouldn’t be lost out the flue?\u003c\/strong\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eNo. The National Fuel Gas Code (NFPA54) and local codes require a minimum ventilation flow of 4 CFM per 1000 Btu\/hr of heater input by either mechanical or gravity ventilation if the heaters themselves are not vented to the outside. This additional ventilation requirement increases the building heat loss and the fuel cost as indicated in this example:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Differential (inside temp less outside design temp)\u003c\/td\u003e\n\u003ctd\u003e65° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor (based on 16′ mounting height)\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Heat Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eVented\u003c\/th\u003e\n\u003cth\u003eUnvented\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ventilation Required:\u003c\/td\u003e\n\u003ctd\u003e0 CFM\u003c\/td\u003e\n\u003ctd\u003e4 CFM per 1000 Btu\/hr = 400 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Loss Due to Ventilation\u003c\/td\u003e\n\u003ctd\u003e0 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003eQ = CFM x 60 min\/hr x TD x 0.018 400x60x65°x0.018=28,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Input Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e128,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow many square feet does a SunStar infrared radiant gas heater cover?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eThe heater model and capacity are not necessarily a function of the square footage of the area needing to be heated. The model generally is chosen after the Btu\/hr heat loss for the building or spot area to be heated has been determined, which is a function of not only the size of the area, but geographic location, building materials, building usage and other factors. Area coverage could be as little as 500 sq. ft for residential garage heaters or as much as 10,000 sq. ft. for a large commercial size heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eAre there applications for which SunStar radiant gas heaters are NOT suitable?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eYou may not use gas-fired infrared heaters inside paint booths or in buildings where explosion-proof lights are required. Although infrared is not ideal as an air curtain, it is very effective in spot-heating work areas inside of doorways, in dock areas and on outdoor docks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow low can i hang my SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eSunStar infrared heaters have been mounted as low as 8′ above the finished floor (in home garages and workshops) to as high as 70′ (in high bay aircraft hangars). The mounting height depends on the Btu\/hr capacity and model of the heater. Please refer to the heater’s specification sheet for minimum recommended mounting height and required clearances to combustible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat extra items are needed for installation?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eDepending on your particular application, you will want to consider the following six accessories for all series of SunStar infrared tube heaters:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eThermostat\u003c\/li\u003e\n\u003cli\u003eManual Cutoff Valve\u003c\/li\u003e\n\u003cli\u003eFlexible Gas Connector (Included as part of the SunStar tube heaters)\u003c\/li\u003e\n\u003cli\u003eSecond Stage Regulator if supply pressure is over 14″ W.C.\u003c\/li\u003e\n\u003cli\u003eVent Cap\u003c\/li\u003e\n\u003cli\u003eChain Kit with S hooks for hanging heater.\u003c\/li\u003e\n\u003cli\u003eEnd Reflector Kit for SIS \u0026amp; SPS Series ( optional, but recommended).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SIU Series, also consider including two additional accessories:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTwo End Reflector Kits per heater ( optional, but recommended)\u003c\/li\u003e\n\u003cli\u003eU-Bend reflector (optional, but recommended)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SG and SGM ceramic heaters, you will not need a vent cap.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow are SunStar infrared radiant gas heaters controlled?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003ePrimarily, the heater is controlled by a line voltage thermostat. Alternatively, you may use a 24-volt thermostat with a relay kit or an on\/off switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is a “TOUGH GUY” Heater?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eTOUGH GUY Emitter tubes use heat-treated aluminized steel tubes that that can withstand higher operating temperatures than other conventional tube materials and is very absorptive of the flame on the inside of the tube and very emissive on the outside, increasing the heating efficiency. The heat treating process provides unsurpassed corrosion resistance to ferrous metal by providing a self-forming, self-healing coating of practically infusible alumina which is impervious to oxygen, carbon, sulfur and the products of combustion of natural and liquefied propane gas and is, therefore, extremely corrosion resistant. TOUGH GUY emitter tubes are highly recommended for high humidity \/ corrosive environments such as dairy barns, swimming pools, greenhouses, or water treatment plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have UL certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eBecause our infrared gas heaters are gas appliances, it is not necessary that they be listed by UL (a nationally recognized testing laboratory – NRTL); however, all of the electrical component parts are UL listed (e.g., the draft inducer motors, which are equipped with CSA and UL approved thermal protectors). Our heaters are certified by C.S.A. (a nationally recognized testing laboratory – NRTL) and carry the C.S.A. seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20 for infrared heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have FM certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eGenerally, Factory Mutual certification (a nationally recognized testing laboratory – NRTL) is applicable to products that cannot be certified at the manufacturer’s facility according to American National Standard and, therefore, need to be certified at the installation site. Our heaters are certified by C.S.A.(a nationally recognized testing laboratory – NRTL) and carry the CSA seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20. Factory Mutual recognizes International Approval Services certification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat are the emission levels of SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eAir-free CO emission levels are 0.0010 – 0.0020%, or 20 to 40 times lower than the maximum acceptable level as indicated in American National Standard Z83.20. SunStar utilizes burners that are made of heavy duty cast iron and are designed to enhance maximum primary and secondary air flow around the venturi assembly. The high velocity of the flame and the delayed flame-quench period minimize the products of combustion which include aldehyde, formic acid, nitrous oxide, and carbon monoxide.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420372234490,"sku":"SGL35-N10","price":2018.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL-Glass-Series-48-35000-BTUhr-Black-Infrared-Patio-Heater-With-Natural-Gas_525881fa-5c89-476b-b770-e439aa4b9036.jpg?v=1795638706"},{"product_id":"sunstar-48-sgl-glass-series-gas-radiant-patio-heater","title":"SunStar SGL Glass Series 48\" 35000 BTU\/hr Black Infrared Patio Heater With Natural Gas","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eLike the radiant warmth from the sun, radiant heat warms people and objects directly at ﬂoor level without ﬁrst heating the surrounding air. Customers can dine and relax under the radiant warmth of the GLASS, and help you to maximize the use of your seating areas during those colder winter months. Designed with high temperature tinted glass, SunStar GLASS is wind resistant up to 40MPH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFactory shipped as a two stage control heater and can be used with optional 3 position switch or optional remote control for ultimate comfort. Operate at ﬁrst stage (as low as 24,000 BTU\/hr) during milder days and operated at full power (as high as 50,000 BTU\/hr) on colder days. Also it can be operated at full power (up to 50,000 BTU\/hr) as a single stage heater by a simple factory supplied jumper wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eWhat's Included\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-Stage 35,000 TO 24,000 BTU Infrared Heater \u003c\/li\u003e\n\u003cli\u003eCeramic Glass 8.94” x 48” Black\u003c\/li\u003e\n\u003cli\u003eSunStar Clearances sign\u003c\/li\u003e\n\u003cli\u003eAngle Mounting Gauge Plate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot Included \u003cem\u003e(Sold Separately)\u003c\/em\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e3 Position Switch Kit (High\/Low\/Off)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo Stage Thermostat Relay Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStainless Steel Gas Connector\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Connection Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Line Pressure Regulator Up To 2 PSIG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeat Shield Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCeiling Fixed Mount Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e15\"-22\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e15\"-30\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eColumn Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e3\" Pole Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e4\" Pole Mounting Bracket Kit \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e12\" Chain Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eOptional 2-Stage Remote Control Available\u003c\/li\u003e\n\u003cli\u003eOutdoor rated.\u003c\/li\u003e\n\u003cli\u003eCan be mounted from horizontal position to 60°.\u003c\/li\u003e\n\u003cli\u003eTwo-stage (high \/ low) models.\u003c\/li\u003e\n\u003cli\u003eAvailable for natural gas and LPG.\u003c\/li\u003e\n\u003cli\u003eChain suspension or wall mounted.\u003c\/li\u003e\n\u003cli\u003eAesthetically designed with glass front to blend with nearly any decor.\u003c\/li\u003e\n\u003cli\u003eCSA Design Certiﬁed -Z83.19 \u0026amp; Z83.26\u003c\/li\u003e\n\u003cli\u003eDesigned for restaurants, residential patios and other hospitality service industries, SunStar GLASS is wind resistant up to 40MPH.\u003c\/li\u003e\n\u003cli\u003eHigh temperature tinted glass provides additional protection on windy days and enhances heater’s aesthetic appeal.\u003c\/li\u003e\n\u003cli\u003eThe SunStar GLASS radiant patio heater is ideal for out door or partially covered dining areas, bars, patios, verandas, smoking areas, vestibules and other outdoor areas.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eClearances above can be as low as 10” with optional heat shield\u003c\/li\u003e\n\u003cli\u003eCovers 12’ by 12’ area with minimal wind conditions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eDirect Spark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eChain Suspension Or Wall\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eCoverage Area\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e144 ft²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e11.5\" D x 48\" W x 9.5\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e55 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBTU Ratings (BTU\/hr)\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh\u003c\/strong\u003e - 35,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e Low\u003c\/strong\u003e - 24,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003e\n\u003cspan\u003eMounting Height\u003c\/span\u003e\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-11' horizontal; 7'-9' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eSpace Between Heaters\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-16' horizontal; 6'-14' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBurner Pressure\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNG\u003c\/strong\u003e - 6.0\" w.c.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLP \u003c\/strong\u003e- \u003cspan\u003e11.0\" W.C.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003eDimensions\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_SGL35-N7_Dimensions-480x480.jpg\" width=\"450\" height=\"450\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003eSGL Clearance to Combustibles\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Angle\u003c\/th\u003e\n\u003cth\u003eCeiling\u003c\/th\u003e\n\u003cth\u003eCeiling*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003cth\u003eBack*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30°\u003c\/td\u003e\n\u003ctd\u003e23\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSide\u003c\/th\u003e\n\u003cth\u003eEnd\u003c\/th\u003e\n\u003cth\u003eBelow\u003c\/th\u003e\n\u003cth\u003eFront\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e*Note: \u003c\/strong\u003e\u003cem\u003e\"Installed w\/optional clearance shield to reduce ceiling \u0026amp; back clearances\u003c\/em\u003e\u003cem\u003e\".\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch1\u003eWarranty\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/1-year_Warranty_Badge_feda9a11-bab7-4ab1-aa50-200fd2fb004d.jpg\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e1-year limited manufacturer warranty on controls\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg width=\"100%\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/3-year_Warranty_Badge.jpg\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e3-year limited manufacturer warranty on the burner assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-IO-SGL-Series-Glass-Patio-Heater-rev-Mar-2019-Manual.pdf\"\u003eInstallation and Owner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-R130-SGL-Series-Patio-Heater-Specs.pdf\"\u003eSpecs Sheet\u003cbr\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-Heater-Sizing-Layout-Guidelines.pdf\"\u003e\u003cspan\u003eSizing \u0026amp; Layout Guidelines\u003c\/span\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_patio_heater_comparisons.pdf\"\u003e\u003cspan\u003eSGL Series Patio Heater Comparison\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_accessories.pdf\"\u003e\u003cspan\u003eSGL Series Glass Patio Heater Accessories\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878760-SGL-Patio-Heater-Column-Mounting-IO.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series - Column Mounting I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878770-SGL-Patio-Heater-Rod-Suspension-IO.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series - Rod Suspension I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/44201630-Form-Retrofit-Remote-Control-SUNSTAR.pdf\"\u003e\u003cspan\u003eSGL Glass Series Retrofit – Remote Control Form\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhy is a SunStar infrared radiant gas heater more efficient than unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003eThe major difference between a gas-fired infrared heating system and a forced hot air heating system is the method used to create a comfortable temperature. Infrared heats the floor slab, the machinery and the people first and then the air by using all three methods of heat transfer: radiation, conduction and convection. The storage of the heat in the slab floor creates a low temperature emitter and a faster recovery time when large overhead doors are opened and closed.With a forced air system, the hot air rises to the ceiling and stratifies, gradually working its way down to thermostat level so that the floor slab never becomes warm enough to be comfortable. It literally acts as a heat sink, draining heat from the air and from personnel standing on the floor. The ceiling area of a high bay building using a forced air system can be easily 30° to 40° warmer than the floor area. In the same type building heated with an infrared system, the temperature is much more uniform and the loft or roof area usually will be at a slightly lower temperature than the floor level… a good condition for minimizing heat loss. Comfort can be maintained with a lower air temperature that will reduce infiltration and heat loss through the walls and roof.In addition, instead of adding Btu\/hr capacity to a computed building heat loss based on the thermal efficiency of a forced air system, the capacity is normally reduced by as much as 15%. An added plus is that an infrared system has minimal power requirements, needing electricity only for burner ignition, the gas valve and the draft inducer (where applicable).It is, therefore, easy to understand that infrared commonly can save 30% to 50% in energy costs over unit heaters, frequently even more.\u003c\/summary\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow do you size infrared when replacing existing forced air unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003cp\u003eAn infrared heating system is always sized at a lower input capacity when compared to forced air (convection) heating. This is due to different modes of heat transfer (radiation vs. convection), thermal mass and minimal stratification between ceiling and floor temperatures. For retrofit purposes, provided the unit heaters are maintaining the desired inside design temperature at ASHRAe design conditions, the following reduction can be utilized when recommending an infrared heating system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eThermal Efficiency\u003c\/th\u003e\n\u003cth\u003e% Reduction in System Sizing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Efficiency Unit Heater\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003e32%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvectional Unit Heater\u003c\/td\u003e\n\u003ctd\u003e62%\u003c\/td\u003e\n\u003ctd\u003e48%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAssuming that the ASHRAE heat loss for a building is 100,000 Btu\/hr, then the heater selection for this building would be as follows:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eInfrared Heater\u003c\/th\u003e\n\u003cth\u003eUnit Heater\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor\u003cbr\u003e(for radiant heating)\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Efficiency\u003cbr\u003e(for convection heating)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Input Required\u003c\/td\u003e\n\u003ctd\u003e85,000 Btu\/hr\u003cbr\u003e(100,000 x 0.85)\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003cbr\u003e(100,000 \/ 0.80)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWouldn’t it be more efficient to use unvented heaters so heat wouldn’t be lost out the flue?\u003c\/strong\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eNo. The National Fuel Gas Code (NFPA54) and local codes require a minimum ventilation flow of 4 CFM per 1000 Btu\/hr of heater input by either mechanical or gravity ventilation if the heaters themselves are not vented to the outside. This additional ventilation requirement increases the building heat loss and the fuel cost as indicated in this example:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Differential (inside temp less outside design temp)\u003c\/td\u003e\n\u003ctd\u003e65° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor (based on 16′ mounting height)\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Heat Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eVented\u003c\/th\u003e\n\u003cth\u003eUnvented\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ventilation Required:\u003c\/td\u003e\n\u003ctd\u003e0 CFM\u003c\/td\u003e\n\u003ctd\u003e4 CFM per 1000 Btu\/hr = 400 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Loss Due to Ventilation\u003c\/td\u003e\n\u003ctd\u003e0 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003eQ = CFM x 60 min\/hr x TD x 0.018 400x60x65°x0.018=28,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Input Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e128,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow many square feet does a SunStar infrared radiant gas heater cover?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eThe heater model and capacity are not necessarily a function of the square footage of the area needing to be heated. The model generally is chosen after the Btu\/hr heat loss for the building or spot area to be heated has been determined, which is a function of not only the size of the area, but geographic location, building materials, building usage and other factors. Area coverage could be as little as 500 sq. ft for residential garage heaters or as much as 10,000 sq. ft. for a large commercial size heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eAre there applications for which SunStar radiant gas heaters are NOT suitable?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eYou may not use gas-fired infrared heaters inside paint booths or in buildings where explosion-proof lights are required. Although infrared is not ideal as an air curtain, it is very effective in spot-heating work areas inside of doorways, in dock areas and on outdoor docks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow low can i hang my SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eSunStar infrared heaters have been mounted as low as 8′ above the finished floor (in home garages and workshops) to as high as 70′ (in high bay aircraft hangars). The mounting height depends on the Btu\/hr capacity and model of the heater. Please refer to the heater’s specification sheet for minimum recommended mounting height and required clearances to combustible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat extra items are needed for installation?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eDepending on your particular application, you will want to consider the following six accessories for all series of SunStar infrared tube heaters:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eThermostat\u003c\/li\u003e\n\u003cli\u003eManual Cutoff Valve\u003c\/li\u003e\n\u003cli\u003eFlexible Gas Connector (Included as part of the SunStar tube heaters)\u003c\/li\u003e\n\u003cli\u003eSecond Stage Regulator if supply pressure is over 14″ W.C.\u003c\/li\u003e\n\u003cli\u003eVent Cap\u003c\/li\u003e\n\u003cli\u003eChain Kit with S hooks for hanging heater.\u003c\/li\u003e\n\u003cli\u003eEnd Reflector Kit for SIS \u0026amp; SPS Series ( optional, but recommended).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SIU Series, also consider including two additional accessories:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTwo End Reflector Kits per heater ( optional, but recommended)\u003c\/li\u003e\n\u003cli\u003eU-Bend reflector (optional, but recommended)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SG and SGM ceramic heaters, you will not need a vent cap.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow are SunStar infrared radiant gas heaters controlled?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003ePrimarily, the heater is controlled by a line voltage thermostat. Alternatively, you may use a 24-volt thermostat with a relay kit or an on\/off switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is a “TOUGH GUY” Heater?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eTOUGH GUY Emitter tubes use heat-treated aluminized steel tubes that that can withstand higher operating temperatures than other conventional tube materials and is very absorptive of the flame on the inside of the tube and very emissive on the outside, increasing the heating efficiency. The heat treating process provides unsurpassed corrosion resistance to ferrous metal by providing a self-forming, self-healing coating of practically infusible alumina which is impervious to oxygen, carbon, sulfur and the products of combustion of natural and liquefied propane gas and is, therefore, extremely corrosion resistant. TOUGH GUY emitter tubes are highly recommended for high humidity \/ corrosive environments such as dairy barns, swimming pools, greenhouses, or water treatment plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have UL certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eBecause our infrared gas heaters are gas appliances, it is not necessary that they be listed by UL (a nationally recognized testing laboratory – NRTL); however, all of the electrical component parts are UL listed (e.g., the draft inducer motors, which are equipped with CSA and UL approved thermal protectors). Our heaters are certified by C.S.A. (a nationally recognized testing laboratory – NRTL) and carry the C.S.A. seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20 for infrared heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have FM certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eGenerally, Factory Mutual certification (a nationally recognized testing laboratory – NRTL) is applicable to products that cannot be certified at the manufacturer’s facility according to American National Standard and, therefore, need to be certified at the installation site. Our heaters are certified by C.S.A.(a nationally recognized testing laboratory – NRTL) and carry the CSA seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20. Factory Mutual recognizes International Approval Services certification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat are the emission levels of SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eAir-free CO emission levels are 0.0010 – 0.0020%, or 20 to 40 times lower than the maximum acceptable level as indicated in American National Standard Z83.20. SunStar utilizes burners that are made of heavy duty cast iron and are designed to enhance maximum primary and secondary air flow around the venturi assembly. The high velocity of the flame and the delayed flame-quench period minimize the products of combustion which include aldehyde, formic acid, nitrous oxide, and carbon monoxide.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420372300026,"sku":"SGL35-N7","price":1716.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL-Glass-Series-48-35000-BTUhr-Black-Infrared-Patio-Heater-With-Natural-Gas_88f464ff-6909-4fb4-bb33-6c8848f886e6.jpg?v=1795638713"},{"product_id":"sunstar-sgl-glass-series-48-35000-btu-hr-black-infrared-patio-heater-with-propane-gas-and-remote","title":"SunStar SGL Glass Series 48\" 35000 BTU\/hr Black Infrared Patio Heater With Propane Gas And Remote","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eLike the radiant warmth from the sun, radiant heat warms people and objects directly at ﬂoor level without ﬁrst heating the surrounding air. Customers can dine and relax under the radiant warmth of the GLASS, and help you to maximize the use of your seating areas during those colder winter months. Designed with high temperature tinted glass, SunStar GLASS is wind resistant up to 40MPH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFactory shipped as a two stage control heater and can be used with optional 3 position switch or optional remote control for ultimate comfort. Operate at ﬁrst stage (as low as 24,000 BTU\/hr) during milder days and operated at full power (as high as 50,000 BTU\/hr) on colder days. Also it can be operated at full power (up to 50,000 BTU\/hr) as a single stage heater by a simple factory supplied jumper wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eWhat's Included\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-Stage 35,000 TO 24,000 BTU Infrared Heater\u003c\/li\u003e\n\u003cli\u003eCeramic Glass 8.94” x 48” Black\u003c\/li\u003e\n\u003cli\u003eSunStar Clearances sign\u003c\/li\u003e\n\u003cli\u003eAngle Mounting Gauge Plat\u003c\/li\u003e\n\u003cli\u003eRemote 2-stage Sunstar\u003c\/li\u003e\n\u003cli\u003eAAA Battery 2 Pack \u003c\/li\u003e\n\u003cli\u003e3 Position Switch Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot Included \u003cem\u003e(Sold Separately)\u003c\/em\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo Stage Thermostat Relay Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStainless Steel Gas Connector\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Connection Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Line Pressure Regulator Up To 2 PSIG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeat Shield Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCeiling Fixed Mount Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e15\"-22\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e15\"-30\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eColumn Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e3\" Pole Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e4\" Pole Mounting Bracket Kit \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e12\" Chain Kit\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eOptional 2-Stage Remote Control Available\u003c\/li\u003e\n\u003cli\u003eOutdoor rated.\u003c\/li\u003e\n\u003cli\u003eCan be mounted from horizontal position to 60°.\u003c\/li\u003e\n\u003cli\u003eTwo-stage (high \/ low) models.\u003c\/li\u003e\n\u003cli\u003eAvailable for natural gas and LPG.\u003c\/li\u003e\n\u003cli\u003eChain suspension or wall mounted.\u003c\/li\u003e\n\u003cli\u003eAesthetically designed with glass front to blend with nearly any decor.\u003c\/li\u003e\n\u003cli\u003eCSA Design Certiﬁed -Z83.19 \u0026amp; Z83.26\u003c\/li\u003e\n\u003cli\u003eDesigned for restaurants, residential patios and other hospitality service industries, SunStar GLASS is wind resistant up to 40MPH.\u003c\/li\u003e\n\u003cli\u003eHigh temperature tinted glass provides additional protection on windy days and enhances heater’s aesthetic appeal.\u003c\/li\u003e\n\u003cli\u003eThe SunStar GLASS radiant patio heater is ideal for out door or partially covered dining areas, bars, patios, verandas, smoking areas, vestibules and other outdoor areas.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eClearances above can be as low as 10” with optional heat shield\u003c\/li\u003e\n\u003cli\u003eCovers 12’ by 12’ area with minimal wind conditions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003ePropane Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eDirect Spark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eChain Suspension Or Wall\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eCoverage Area\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e144 ft²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e11.5\" D x 48\" W x 9.5\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e55 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBTU Ratings (BTU\/hr)\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh\u003c\/strong\u003e - 35,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e Low\u003c\/strong\u003e - 24,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003e\n\u003cspan\u003eMounting Height\u003c\/span\u003e\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-11' horizontal; 7'-9' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eSpace Between Heaters\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-16' horizontal; 6'-14' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBurner Pressure\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNG\u003c\/strong\u003e - 6.0\" w.c.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLP \u003c\/strong\u003e- \u003cspan\u003e11.0\" W.C.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003eDimensions\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_SGL35-N7_Dimensions-480x480.jpg\" width=\"450\" height=\"450\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003eSGL Clearance to Combustibles\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Angle\u003c\/th\u003e\n\u003cth\u003eCeiling\u003c\/th\u003e\n\u003cth\u003eCeiling*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003cth\u003eBack*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30°\u003c\/td\u003e\n\u003ctd\u003e23\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSide\u003c\/th\u003e\n\u003cth\u003eEnd\u003c\/th\u003e\n\u003cth\u003eBelow\u003c\/th\u003e\n\u003cth\u003eFront\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e*Note: \u003c\/strong\u003e\u003cem\u003e\"Installed w\/optional clearance shield to reduce ceiling \u0026amp; back clearances\u003c\/em\u003e\u003cem\u003e\".\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch1\u003eWarranty\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/1-year_Warranty_Badge_feda9a11-bab7-4ab1-aa50-200fd2fb004d.jpg\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e1-year limited manufacturer warranty on controls\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/3-year_Warranty_Badge.jpg\" width=\"100%\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e3-year limited manufacturer warranty on the burner assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-IO-SGL-Series-Glass-Patio-Heater-rev-Mar-2019-Manual.pdf\"\u003eInstallation and Owner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-R130-SGL-Series-Patio-Heater-Specs.pdf\"\u003eSpecs Sheet\u003cbr\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-Heater-Sizing-Layout-Guidelines.pdf\"\u003e\u003cspan\u003eSizing \u0026amp; Layout Guidelines\u003c\/span\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_patio_heater_comparisons.pdf\"\u003e\u003cspan\u003eSGL Series Patio Heater Comparison\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_accessories.pdf\"\u003e\u003cspan\u003eSGL Series Glass Patio Heater Accessories\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878760-SGL-Patio-Heater-Column-Mounting-IO.pdf\"\u003e\u003cspan\u003eSGL Glass Series - Column Mounting I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878770-SGL-Patio-Heater-Rod-Suspension-IO.pdf\"\u003e\u003cspan\u003eSGL Glass Series - Rod Suspension I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/44201630-Form-Retrofit-Remote-Control-SUNSTAR.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series Retrofit – Remote Control Form\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhy is a SunStar infrared radiant gas heater more efficient than unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003eThe major difference between a gas-fired infrared heating system and a forced hot air heating system is the method used to create a comfortable temperature. Infrared heats the floor slab, the machinery and the people first and then the air by using all three methods of heat transfer: radiation, conduction and convection. The storage of the heat in the slab floor creates a low temperature emitter and a faster recovery time when large overhead doors are opened and closed.With a forced air system, the hot air rises to the ceiling and stratifies, gradually working its way down to thermostat level so that the floor slab never becomes warm enough to be comfortable. It literally acts as a heat sink, draining heat from the air and from personnel standing on the floor. The ceiling area of a high bay building using a forced air system can be easily 30° to 40° warmer than the floor area. In the same type building heated with an infrared system, the temperature is much more uniform and the loft or roof area usually will be at a slightly lower temperature than the floor level… a good condition for minimizing heat loss. Comfort can be maintained with a lower air temperature that will reduce infiltration and heat loss through the walls and roof.In addition, instead of adding Btu\/hr capacity to a computed building heat loss based on the thermal efficiency of a forced air system, the capacity is normally reduced by as much as 15%. An added plus is that an infrared system has minimal power requirements, needing electricity only for burner ignition, the gas valve and the draft inducer (where applicable).It is, therefore, easy to understand that infrared commonly can save 30% to 50% in energy costs over unit heaters, frequently even more.\u003c\/summary\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow do you size infrared when replacing existing forced air unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003cp\u003eAn infrared heating system is always sized at a lower input capacity when compared to forced air (convection) heating. This is due to different modes of heat transfer (radiation vs. convection), thermal mass and minimal stratification between ceiling and floor temperatures. For retrofit purposes, provided the unit heaters are maintaining the desired inside design temperature at ASHRAe design conditions, the following reduction can be utilized when recommending an infrared heating system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eThermal Efficiency\u003c\/th\u003e\n\u003cth\u003e% Reduction in System Sizing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Efficiency Unit Heater\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003e32%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvectional Unit Heater\u003c\/td\u003e\n\u003ctd\u003e62%\u003c\/td\u003e\n\u003ctd\u003e48%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAssuming that the ASHRAE heat loss for a building is 100,000 Btu\/hr, then the heater selection for this building would be as follows:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eInfrared Heater\u003c\/th\u003e\n\u003cth\u003eUnit Heater\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor\u003cbr\u003e(for radiant heating)\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Efficiency\u003cbr\u003e(for convection heating)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Input Required\u003c\/td\u003e\n\u003ctd\u003e85,000 Btu\/hr\u003cbr\u003e(100,000 x 0.85)\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003cbr\u003e(100,000 \/ 0.80)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWouldn’t it be more efficient to use unvented heaters so heat wouldn’t be lost out the flue?\u003c\/strong\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eNo. The National Fuel Gas Code (NFPA54) and local codes require a minimum ventilation flow of 4 CFM per 1000 Btu\/hr of heater input by either mechanical or gravity ventilation if the heaters themselves are not vented to the outside. This additional ventilation requirement increases the building heat loss and the fuel cost as indicated in this example:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Differential (inside temp less outside design temp)\u003c\/td\u003e\n\u003ctd\u003e65° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor (based on 16′ mounting height)\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Heat Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eVented\u003c\/th\u003e\n\u003cth\u003eUnvented\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ventilation Required:\u003c\/td\u003e\n\u003ctd\u003e0 CFM\u003c\/td\u003e\n\u003ctd\u003e4 CFM per 1000 Btu\/hr = 400 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Loss Due to Ventilation\u003c\/td\u003e\n\u003ctd\u003e0 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003eQ = CFM x 60 min\/hr x TD x 0.018 400x60x65°x0.018=28,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Input Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e128,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow many square feet does a SunStar infrared radiant gas heater cover?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eThe heater model and capacity are not necessarily a function of the square footage of the area needing to be heated. The model generally is chosen after the Btu\/hr heat loss for the building or spot area to be heated has been determined, which is a function of not only the size of the area, but geographic location, building materials, building usage and other factors. Area coverage could be as little as 500 sq. ft for residential garage heaters or as much as 10,000 sq. ft. for a large commercial size heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eAre there applications for which SunStar radiant gas heaters are NOT suitable?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eYou may not use gas-fired infrared heaters inside paint booths or in buildings where explosion-proof lights are required. Although infrared is not ideal as an air curtain, it is very effective in spot-heating work areas inside of doorways, in dock areas and on outdoor docks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow low can i hang my SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eSunStar infrared heaters have been mounted as low as 8′ above the finished floor (in home garages and workshops) to as high as 70′ (in high bay aircraft hangars). The mounting height depends on the Btu\/hr capacity and model of the heater. Please refer to the heater’s specification sheet for minimum recommended mounting height and required clearances to combustible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat extra items are needed for installation?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eDepending on your particular application, you will want to consider the following six accessories for all series of SunStar infrared tube heaters:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eThermostat\u003c\/li\u003e\n\u003cli\u003eManual Cutoff Valve\u003c\/li\u003e\n\u003cli\u003eFlexible Gas Connector (Included as part of the SunStar tube heaters)\u003c\/li\u003e\n\u003cli\u003eSecond Stage Regulator if supply pressure is over 14″ W.C.\u003c\/li\u003e\n\u003cli\u003eVent Cap\u003c\/li\u003e\n\u003cli\u003eChain Kit with S hooks for hanging heater.\u003c\/li\u003e\n\u003cli\u003eEnd Reflector Kit for SIS \u0026amp; SPS Series ( optional, but recommended).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SIU Series, also consider including two additional accessories:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTwo End Reflector Kits per heater ( optional, but recommended)\u003c\/li\u003e\n\u003cli\u003eU-Bend reflector (optional, but recommended)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SG and SGM ceramic heaters, you will not need a vent cap.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow are SunStar infrared radiant gas heaters controlled?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003ePrimarily, the heater is controlled by a line voltage thermostat. Alternatively, you may use a 24-volt thermostat with a relay kit or an on\/off switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is a “TOUGH GUY” Heater?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eTOUGH GUY Emitter tubes use heat-treated aluminized steel tubes that that can withstand higher operating temperatures than other conventional tube materials and is very absorptive of the flame on the inside of the tube and very emissive on the outside, increasing the heating efficiency. The heat treating process provides unsurpassed corrosion resistance to ferrous metal by providing a self-forming, self-healing coating of practically infusible alumina which is impervious to oxygen, carbon, sulfur and the products of combustion of natural and liquefied propane gas and is, therefore, extremely corrosion resistant. TOUGH GUY emitter tubes are highly recommended for high humidity \/ corrosive environments such as dairy barns, swimming pools, greenhouses, or water treatment plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have UL certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eBecause our infrared gas heaters are gas appliances, it is not necessary that they be listed by UL (a nationally recognized testing laboratory – NRTL); however, all of the electrical component parts are UL listed (e.g., the draft inducer motors, which are equipped with CSA and UL approved thermal protectors). Our heaters are certified by C.S.A. (a nationally recognized testing laboratory – NRTL) and carry the C.S.A. seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20 for infrared heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have FM certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eGenerally, Factory Mutual certification (a nationally recognized testing laboratory – NRTL) is applicable to products that cannot be certified at the manufacturer’s facility according to American National Standard and, therefore, need to be certified at the installation site. Our heaters are certified by C.S.A.(a nationally recognized testing laboratory – NRTL) and carry the CSA seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20. Factory Mutual recognizes International Approval Services certification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat are the emission levels of SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eAir-free CO emission levels are 0.0010 – 0.0020%, or 20 to 40 times lower than the maximum acceptable level as indicated in American National Standard Z83.20. SunStar utilizes burners that are made of heavy duty cast iron and are designed to enhance maximum primary and secondary air flow around the venturi assembly. The high velocity of the flame and the delayed flame-quench period minimize the products of combustion which include aldehyde, formic acid, nitrous oxide, and carbon monoxide.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420372726010,"sku":"SGL35-L10","price":2018.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL-Glass-Series-48-35000-BTUhr-Black-Infrared-Patio-Heater-With-Natural-Gas_465e088f-f671-41eb-a29f-9b7c0aa4831a.jpg?v=1795638716"},{"product_id":"sunstar-sgl-glass-series-48-35000-btu-hr-black-infrared-patio-heater-with-propane-gas","title":"SunStar SGL Glass Series 48\" 35000 BTU\/hr Black Infrared Patio Heater With Propane Gas","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eLike the radiant warmth from the sun, radiant heat warms people and objects directly at ﬂoor level without ﬁrst heating the surrounding air. Customers can dine and relax under the radiant warmth of the GLASS, and help you to maximize the use of your seating areas during those colder winter months. Designed with high temperature tinted glass, SunStar GLASS is wind resistant up to 40MPH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFactory shipped as a two stage control heater and can be used with optional 3 position switch or optional remote control for ultimate comfort. Operate at ﬁrst stage (as low as 24,000 BTU\/hr) during milder days and operated at full power (as high as 50,000 BTU\/hr) on colder days. Also it can be operated at full power (up to 50,000 BTU\/hr) as a single stage heater by a simple factory supplied jumper wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eWhat's Included\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-Stage 35,000 TO 24,000 BTU Infrared Heater\u003c\/li\u003e\n\u003cli\u003eCeramic Glass 8.94” x 48” Black\u003c\/li\u003e\n\u003cli\u003eSunStar Clearances sign\u003c\/li\u003e\n\u003cli\u003eAngle Mounting Gauge Plate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot Included \u003cem\u003e(Sold Separately)\u003c\/em\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e3 Position Switch Kit (High\/Low\/Off)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo Stage Thermostat Relay Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStainless Steel Gas Connector\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Connection Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGas Line Pressure Regulator Up To 2 PSIG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeat Shield Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCeiling Fixed Mount Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e15\"-22\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e15\"-30\" Wall\/Ceiling Telescopic Mounting Bracket Kit\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eColumn Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e3\" Pole Mounting Arm Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e4\" Pole Mounting Bracket Kit \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e12\" Chain Kit\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eOptional 2-Stage Remote Control Available\u003c\/li\u003e\n\u003cli\u003eOutdoor rated.\u003c\/li\u003e\n\u003cli\u003eCan be mounted from horizontal position to 60°.\u003c\/li\u003e\n\u003cli\u003eTwo-stage (high \/ low) models.\u003c\/li\u003e\n\u003cli\u003eAvailable for natural gas and LPG.\u003c\/li\u003e\n\u003cli\u003eChain suspension or wall mounted.\u003c\/li\u003e\n\u003cli\u003eAesthetically designed with glass front to blend with nearly any decor.\u003c\/li\u003e\n\u003cli\u003eCSA Design Certiﬁed -Z83.19 \u0026amp; Z83.26\u003c\/li\u003e\n\u003cli\u003eDesigned for restaurants, residential patios and other hospitality service industries, SunStar GLASS is wind resistant up to 40MPH.\u003c\/li\u003e\n\u003cli\u003eHigh temperature tinted glass provides additional protection on windy days and enhances heater’s aesthetic appeal.\u003c\/li\u003e\n\u003cli\u003eThe SunStar GLASS radiant patio heater is ideal for out door or partially covered dining areas, bars, patios, verandas, smoking areas, vestibules and other outdoor areas.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eClearances above can be as low as 10” with optional heat shield\u003c\/li\u003e\n\u003cli\u003eCovers 12’ by 12’ area with minimal wind conditions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003ePropane Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eDirect Spark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eChain Suspension Or Wall\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eCoverage Area\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e144 ft²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e11.5\" D x 48\" W x 9.5\" H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e55 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBTU Ratings (BTU\/hr)\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh\u003c\/strong\u003e - 35,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e Low\u003c\/strong\u003e - 24,000 (LP\/NG)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003e\n\u003cspan\u003eMounting Height\u003c\/span\u003e\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-11' horizontal; 7'-9' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eSpace Between Heaters\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e8'-16' horizontal; 6'-14' angled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth\u003eBurner Pressure\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNG\u003c\/strong\u003e - 6.0\" w.c.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLP \u003c\/strong\u003e- \u003cspan\u003e11.0\" W.C.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003eDimensions\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_SGL35-N7_Dimensions-480x480.jpg\" width=\"450\" height=\"450\"\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003eSGL Clearance to Combustibles\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Angle\u003c\/th\u003e\n\u003cth\u003eCeiling\u003c\/th\u003e\n\u003cth\u003eCeiling*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003cth\u003eBack*\u003cbr\u003ew\/Shield\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003ctd\u003e10\"\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30°\u003c\/td\u003e\n\u003ctd\u003e23\"\u003c\/td\u003e\n\u003ctd\u003e14\"\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60°\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSide\u003c\/th\u003e\n\u003cth\u003eEnd\u003c\/th\u003e\n\u003cth\u003eBelow\u003c\/th\u003e\n\u003cth\u003eFront\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e40\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003e*Note: \u003c\/strong\u003e\u003cem\u003e\"Installed w\/optional clearance shield to reduce ceiling \u0026amp; back clearances\u003c\/em\u003e\u003cem\u003e\".\u003c\/em\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch1\u003eWarranty\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/1-year_Warranty_Badge_feda9a11-bab7-4ab1-aa50-200fd2fb004d.jpg\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e1-year limited manufacturer warranty on controls\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"40%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/3-year_Warranty_Badge.jpg\" width=\"100%\"\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\n\u003cp\u003e3-year limited manufacturer warranty on the burner assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-IO-SGL-Series-Glass-Patio-Heater-rev-Mar-2019-Manual.pdf\"\u003eInstallation and Owner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-R130-SGL-Series-Patio-Heater-Specs.pdf\"\u003eSpecs Sheet\u003cbr\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar-Heater-Sizing-Layout-Guidelines.pdf\"\u003e\u003cspan\u003eSizing \u0026amp; Layout Guidelines\u003c\/span\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_patio_heater_comparisons.pdf\"\u003e\u003cspan\u003eSGL Series Patio Heater Comparison\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/SunStar_sgl_glass_series_patio_heater_accessories.pdf\"\u003e\u003cspan\u003eSGL Series Glass Patio Heater Accessories\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878760-SGL-Patio-Heater-Column-Mounting-IO.pdf\"\u003e\u003cspan\u003eSGL Glass Series - Column Mounting I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Sunstar-43878770-SGL-Patio-Heater-Rod-Suspension-IO.pdf\"\u003e\u003cspan\u003eSGL Glass Series - Rod Suspension I \u0026amp; O Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/44201630-Form-Retrofit-Remote-Control-SUNSTAR.pdf\" rel=\"noopener\"\u003e\u003cspan\u003eSGL Glass Series Retrofit – Remote Control Form\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhy is a SunStar infrared radiant gas heater more efficient than unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003eThe major difference between a gas-fired infrared heating system and a forced hot air heating system is the method used to create a comfortable temperature. Infrared heats the floor slab, the machinery and the people first and then the air by using all three methods of heat transfer: radiation, conduction and convection. The storage of the heat in the slab floor creates a low temperature emitter and a faster recovery time when large overhead doors are opened and closed.With a forced air system, the hot air rises to the ceiling and stratifies, gradually working its way down to thermostat level so that the floor slab never becomes warm enough to be comfortable. It literally acts as a heat sink, draining heat from the air and from personnel standing on the floor. The ceiling area of a high bay building using a forced air system can be easily 30° to 40° warmer than the floor area. In the same type building heated with an infrared system, the temperature is much more uniform and the loft or roof area usually will be at a slightly lower temperature than the floor level… a good condition for minimizing heat loss. Comfort can be maintained with a lower air temperature that will reduce infiltration and heat loss through the walls and roof.In addition, instead of adding Btu\/hr capacity to a computed building heat loss based on the thermal efficiency of a forced air system, the capacity is normally reduced by as much as 15%. An added plus is that an infrared system has minimal power requirements, needing electricity only for burner ignition, the gas valve and the draft inducer (where applicable).It is, therefore, easy to understand that infrared commonly can save 30% to 50% in energy costs over unit heaters, frequently even more.\u003c\/summary\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow do you size infrared when replacing existing forced air unit heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003cp\u003eAn infrared heating system is always sized at a lower input capacity when compared to forced air (convection) heating. This is due to different modes of heat transfer (radiation vs. convection), thermal mass and minimal stratification between ceiling and floor temperatures. For retrofit purposes, provided the unit heaters are maintaining the desired inside design temperature at ASHRAe design conditions, the following reduction can be utilized when recommending an infrared heating system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eThermal Efficiency\u003c\/th\u003e\n\u003cth\u003e% Reduction in System Sizing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Efficiency Unit Heater\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003ctd\u003e32%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConvectional Unit Heater\u003c\/td\u003e\n\u003ctd\u003e62%\u003c\/td\u003e\n\u003ctd\u003e48%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAssuming that the ASHRAE heat loss for a building is 100,000 Btu\/hr, then the heater selection for this building would be as follows:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eInfrared Heater\u003c\/th\u003e\n\u003cth\u003eUnit Heater\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor\u003cbr\u003e(for radiant heating)\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Efficiency\u003cbr\u003e(for convection heating)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Input Required\u003c\/td\u003e\n\u003ctd\u003e85,000 Btu\/hr\u003cbr\u003e(100,000 x 0.85)\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003cbr\u003e(100,000 \/ 0.80)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWouldn’t it be more efficient to use unvented heaters so heat wouldn’t be lost out the flue?\u003c\/strong\u003e\u003cbr\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eNo. The National Fuel Gas Code (NFPA54) and local codes require a minimum ventilation flow of 4 CFM per 1000 Btu\/hr of heater input by either mechanical or gravity ventilation if the heaters themselves are not vented to the outside. This additional ventilation requirement increases the building heat loss and the fuel cost as indicated in this example:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Differential (inside temp less outside design temp)\u003c\/td\u003e\n\u003ctd\u003e65° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding Heat Loss\u003c\/td\u003e\n\u003ctd\u003e125,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Compensation Factor (based on 16′ mounting height)\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared Heat Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eVented\u003c\/th\u003e\n\u003cth\u003eUnvented\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ventilation Required:\u003c\/td\u003e\n\u003ctd\u003e0 CFM\u003c\/td\u003e\n\u003ctd\u003e4 CFM per 1000 Btu\/hr = 400 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Loss Due to Ventilation\u003c\/td\u003e\n\u003ctd\u003e0 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003eQ = CFM x 60 min\/hr x TD x 0.018 400x60x65°x0.018=28,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Input Required\u003c\/td\u003e\n\u003ctd\u003e100,000 Btu\/hr\u003c\/td\u003e\n\u003ctd\u003e128,080 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow many square feet does a SunStar infrared radiant gas heater cover?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eThe heater model and capacity are not necessarily a function of the square footage of the area needing to be heated. The model generally is chosen after the Btu\/hr heat loss for the building or spot area to be heated has been determined, which is a function of not only the size of the area, but geographic location, building materials, building usage and other factors. Area coverage could be as little as 500 sq. ft for residential garage heaters or as much as 10,000 sq. ft. for a large commercial size heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eAre there applications for which SunStar radiant gas heaters are NOT suitable?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eYou may not use gas-fired infrared heaters inside paint booths or in buildings where explosion-proof lights are required. Although infrared is not ideal as an air curtain, it is very effective in spot-heating work areas inside of doorways, in dock areas and on outdoor docks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow low can i hang my SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eSunStar infrared heaters have been mounted as low as 8′ above the finished floor (in home garages and workshops) to as high as 70′ (in high bay aircraft hangars). The mounting height depends on the Btu\/hr capacity and model of the heater. Please refer to the heater’s specification sheet for minimum recommended mounting height and required clearances to combustible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat extra items are needed for installation?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eDepending on your particular application, you will want to consider the following six accessories for all series of SunStar infrared tube heaters:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eThermostat\u003c\/li\u003e\n\u003cli\u003eManual Cutoff Valve\u003c\/li\u003e\n\u003cli\u003eFlexible Gas Connector (Included as part of the SunStar tube heaters)\u003c\/li\u003e\n\u003cli\u003eSecond Stage Regulator if supply pressure is over 14″ W.C.\u003c\/li\u003e\n\u003cli\u003eVent Cap\u003c\/li\u003e\n\u003cli\u003eChain Kit with S hooks for hanging heater.\u003c\/li\u003e\n\u003cli\u003eEnd Reflector Kit for SIS \u0026amp; SPS Series ( optional, but recommended).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SIU Series, also consider including two additional accessories:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTwo End Reflector Kits per heater ( optional, but recommended)\u003c\/li\u003e\n\u003cli\u003eU-Bend reflector (optional, but recommended)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor the SG and SGM ceramic heaters, you will not need a vent cap.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eHow are SunStar infrared radiant gas heaters controlled?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003ePrimarily, the heater is controlled by a line voltage thermostat. Alternatively, you may use a 24-volt thermostat with a relay kit or an on\/off switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is a “TOUGH GUY” Heater?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eTOUGH GUY Emitter tubes use heat-treated aluminized steel tubes that that can withstand higher operating temperatures than other conventional tube materials and is very absorptive of the flame on the inside of the tube and very emissive on the outside, increasing the heating efficiency. The heat treating process provides unsurpassed corrosion resistance to ferrous metal by providing a self-forming, self-healing coating of practically infusible alumina which is impervious to oxygen, carbon, sulfur and the products of combustion of natural and liquefied propane gas and is, therefore, extremely corrosion resistant. TOUGH GUY emitter tubes are highly recommended for high humidity \/ corrosive environments such as dairy barns, swimming pools, greenhouses, or water treatment plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have UL certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eBecause our infrared gas heaters are gas appliances, it is not necessary that they be listed by UL (a nationally recognized testing laboratory – NRTL); however, all of the electrical component parts are UL listed (e.g., the draft inducer motors, which are equipped with CSA and UL approved thermal protectors). Our heaters are certified by C.S.A. (a nationally recognized testing laboratory – NRTL) and carry the C.S.A. seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20 for infrared heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eDo SunStar infrared radiant gas heaters have FM certification?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eGenerally, Factory Mutual certification (a nationally recognized testing laboratory – NRTL) is applicable to products that cannot be certified at the manufacturer’s facility according to American National Standard and, therefore, need to be certified at the installation site. Our heaters are certified by C.S.A.(a nationally recognized testing laboratory – NRTL) and carry the CSA seal. All heaters are tested and meet or exceed all safety requirements set forth in American National Standard Z83.20. Factory Mutual recognizes International Approval Services certification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat are the emission levels of SunStar infrared radiant gas heaters?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003csummary\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cspan\u003eAir-free CO emission levels are 0.0010 – 0.0020%, or 20 to 40 times lower than the maximum acceptable level as indicated in American National Standard Z83.20. SunStar utilizes burners that are made of heavy duty cast iron and are designed to enhance maximum primary and secondary air flow around the venturi assembly. The high velocity of the flame and the delayed flame-quench period minimize the products of combustion which include aldehyde, formic acid, nitrous oxide, and carbon monoxide.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"SunStar","offers":[{"title":"Default Title","offer_id":68420372824314,"sku":"SGL35-L7","price":1716.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/files\/SunStar-SGL-Glass-Series-48-35000-BTUhr-Black-Infrared-Patio-Heater-With-Natural-Gas_3e9720e2-269d-47ac-a290-97c025bd5c2f.jpg?v=1795638721"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/8625\/1002\/collections\/Outdoor_Kitchen_Equipment_Packages_84cc34e2-5d10-41ef-8337-39186c30775f.png?v=1795640711","url":"https:\/\/agentbbq.com\/collections\/sunstar.oembed","provider":"Agent BBQ","version":"1.0","type":"link"}